8. Thread the fill adapter port into the lower of the two HP
ports. Attach a 9/16" socket to a torque wrench and tighten
the fill adapter port (23) to 90±3 in/lbs.
CAUTION:
Do not over torque. Damage will
result to the fill adapter port.
9. SeA LV-2 with a pin-type pressure indicator (27a):
a. Drop a new, lubricated o-ring (27c) into the pin indicator
body (27b); make sure it is properly seated in the small
recess inside the body. Drop the washer (27d) over the
o-ring, making sure it is laying flat atop the o-ring.
b. Insert the spring (27e) into the indicator body and insert
the pin (27f) into the spring. Place the retaining screw
(27g) on top of the pin and press the retaining screw
against the indicator body. While keeping the retaining
screw pressed against the indicator body, turn the
indicator body counterclockwise to engage the screw
threads.
27f
27e
27b
27g
Turn body to
engage threads
c. Using a 1/8" hex key socket, tighten the retaining
screw by turning it clockwise until it stops. Install a
new, lubricated o-ring (22) onto the threaded end of
the indicator body.
d. Thread the pressure indicator into the upper HP port
until firmly finger tight, then tighten with a valve hand
wheel tool (p/n 053035).
10. SeA LV-2 with a dial-type pressure indicator (27):
a. Install a new, lubricated o-ring (22) onto the dial
pressure indicator (27). Thread the pressure indicator
into the upper HP port and tighten using a 7/8" crow
foot wrench and torque to 45±3 in/lbs.
CAUTION:
Do not damage fill adapter port (23).
CAUTION:
Do not lubricate the burst plug (6).
11. Thread a new, unlubricated burst plug (6) into the lower
port on the first stage body (the side opposite of the fill
adapter). Attach a 3/8" socket to a torque wrench and torque
the burst plug to 90±3 in/lbs.