Safety instructions

Safety instructions for the installation according to UL

2.3
Safety instructions for the installation according to UL
Original − English
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number
E236341)
Ratings
Input 18 ... 30 V DC , max. 4 A
ƒ
ACCU−Pack and CAPS−Pack: max 0.6 A
ƒ
Max. ambient temperature 50 °C.
ƒ
Optional communication ratings:
ƒ
– RS232−Connection: max. 3 A
– USB−Connection: max. 1 A
– PS/2−Connection: max. 1 A
– LAN−Connection: Standard ISDN or RJ45
– DVI−Connection: max. 1 A
J
Warnings!
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
ƒ
ƒ
Battery
ƒ
ƒ
ƒ
12
Use copper wire only.
AWG 18 ... AWG 12 (0.82 mm
Torque 5...7 lb−in (0.5 ... 0.6 Nm)
Replace battery with any from the list below, Part No. CR 2450 only. Use of
another battery may present a risk of fire or explosion.
Recommended CR2450 (R/C, BBVC2) types:
Renata Part.no. CR2450N, Sony Corp. part no. CR2450B, Toshiba part no.
CR2450, Varta part no. CR2450, Matsushita part no. CR2450
Battery may explode if mistreated. Do not recharge, disassemble, dispose of
in fire or heat above 100 °C (212 °F).
Dispose of used battery according to the regulation of recycling or waste.
l
2
2
... 3.3 mm
)
BA_CPCx8xx EN 4.0