H-Tronic AL 600 compact Manual

Automatic charger
Hide thumbs Also See for AL 600 compact:

Advertisement

Quick Links

GB
Automatic charger AL 600 compact
Before using the device, please consider the instructions in this manual.
It is required by law that we give you important instructions for your own safety and make you
aware of how you can avoid damage to people, the device and other facilities.
If this manual is not taken into consideration, the manufacturer is not liable for any damage that
results from negligence or deliberate disregard of the manual.

Danger during charger operation

The charger is produced according to the state of the art and approved safety-related regulations.
However, in case of maloperation or misuse, there is the threat to
-physical condition and life of the user or third parties,
-the charger and equipment of the operator.
Every person who deals with the set-up, operation, maintenance and Servicing of the charger, must
be either accordingly qualified, acquire or have knowledge in handling chargers and consider this
manual in detail.
Errors affecting safety must be avoided and if necessary fixed immediately.
To ensure safe operation, the operator must consider the safety instructions and warnings included
in the manual.

Intended use

The device is designed for automatic charge and buffering of lead batteries with 2, 6 or 12V
terminal tension. A sliding switch carries out the set-up of the battery voltage.
Possible battery types are lead-gel, lead-fleece or lead-acid-batteries.
Primary batteries (zinc-carbon, alkaline, etc.) or other battery types must not be plugged in or
charged.
Another mode of operation other than the one specified is not allowed and results in the damage of
the product.
In addition, this is linked with dangers, such as short-circuit, firing, electric shock etc.
The I-U-charging concept charges the lead-battery with constant current of 600 mA (0,6A) until the
end of charge voltage is reached for the respective battery.
The charger recognises this and switches to constant current in order to adjust the charging current
down (Maintenance charger). The battery charger is therefore maintained at an ideal level.
As a result, the battery can be plugged into the charger for a longer period of time. This is the
reason why this device is suitable for "over wintering". The luminous display on the charger always
gives information on the current operating status.
The plug charger is protected against overcharge and short-term short-circuit (<1min.). The polarity
on the charging output must be taken into consideration. A protective circuit avoids charging in case
of incorrect poling that could destroy the battery as well as the charger. Incorrect poling will be
indicated by a red light. The connection is carried out by marked battery terminal clamps. By means
of safety switching the charging clamps conduct no electric charge as long as they are not connected
to a battery. It is therefore not possible to measure the current on the open charging clamps.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL 600 compact and is the answer not in the manual?

Questions and answers

Summary of Contents for H-Tronic AL 600 compact

  • Page 1 Automatic charger AL 600 compact Before using the device, please consider the instructions in this manual. It is required by law that we give you important instructions for your own safety and make you aware of how you can avoid damage to people, the device and other facilities.
  • Page 2 Note! As for safety, this device has left the factory in a faultless condition. In order to maintain this condition and ensure a safe operation, the user must consider the safety instructions and warnings included in this manual. Operating conditions The charger may only be connected and used in well-ventilated, dry interiors as well as only in a small alternate current voltage of 230V/50 Hz.
  • Page 3 Detach the battery first and only then interrupt the operating voltage. When using products that get in touch with electric charge, the valid VDE-regulations, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 must be complied with. Before opening the device, pull out or secure the mains plug first so the device is dead.
  • Page 4 In case of fault detection (damage) of the cable, the device must be disposed of immediately. Only start using the device outside of the vehicle. Ensure that a secure and stable connection is established when connecting the battery charging clamps. Operating note The device heats up when operating.
  • Page 5 The device is characterised by the following properties: • short-circuit and reverse-polarity protection • Constant charging end voltage • No charging if battery is connected with reverse-polarity • Charging is only carried out if the battery is connected correctly • Visual display, for net, charging and reverse-polarity This article was verified according to the EG-regulation (89/336/EWG (EMVG as of 09/11/1992, electromagnetic compatibility) and complies with the legal regulations.
  • Page 6 exceed approx. 50 °C. If by accident the battery is poled incorrectly then being connected to the charger, this will be signaled by a red LED “reverse poled” and the charge current will be switched off automatically. Note • When charging batteries it is necessary to ensure that the connection of the batteries are correctly poled.
  • Page 7 You comply with the legal obligations and contribute to the environmental protection. This user manual is a publication of H-Tronic GmbH, Industriegebiet Dienhof 11, 92242 Hirschau.

Table of Contents