Avaya Virtual Services Platform 7000 Series Installation Manual page 42

Hide thumbs Also See for Virtual Services Platform 7000 Series:
Table of Contents

Advertisement

Switch installation
42
VSP 7000 installation
LED
State
Amethyst (Solid)
Amethyst (Blinking)
Amethyst / Ruby
(Alternating)
Sapphire / Ruby
(Alternating)
Sapphire (Blink x3) /
Ruby (Solid)
Amethyst (Blink x3) /
Ruby (Solid)
Comments? infodev@avaya.com
Description
The fan tray in position 1/2 is back to
front airflow and is operating
normally.
The fan tray in position 1/2 is back to
front airflow and has degraded.
Check for a fan failure and replace if
necessary.
The fan tray in position 1/2 does not
match the front to back airflow mode
of the power supply. You must
replace the fan tray with a front to
back airflow model.
The fan tray in position 1/2 does not
match the back to front airflow mode
of the power supply. You must
replace the fan tray with a back to
front airflow model.
The fan tray in position 1/2 has
degraded and does not match the
front to back airflow mode of the
power supply. You must replace the
fan tray with a front to back airflow
model.
The fan tray in position 1/2 has
degraded and does not match the
back to front airflow mode of the
power supply. You must replace the
fan tray with a back to front airflow
model.
July 2013