Error Symptoms
NOTE:
Ensure that the diskette drive is configured
correctly in Configuration/Setup Utility and its
read/write head is clean before diagnosing any
diskette drive problems.
Media and drive are
mismatched.
Diskette drive does not
work.
Diskette drive read/write
error.
Diskette drive LED comes
on for more than 2 minutes
when reading data.
Diskette Drive
1. Ensure that the diskette
drive is configured
correctly in the Disk
Drives of Configuration/
Setup Utility. See "Hard
Disk Drive" on page 4.
2. Ensure that the diskette
drive is correctly
formatted.
3. Diskette drive
connection/cable
4. Diskette drive
5. System board
1. Ensure that the diskette
drive is not set to
[None] in the Disk
Drives of Configuration/
Setup Utility. See "Hard
Disk Drive" on page 4.
2. Diskette drive power
3. Diskette drive
connection/cable
4. Diskette drive
5. System board
1. Diskette.
2. Ensure that the diskette
drive is not set to [Write
protect] in the Security
Options of
Configuration/Setup
Utility.
3. Diskette drive cable.
4. Diskette drive.
5. System board.
1. Diskette
2. Diskette drive
connection/cable
3. Diskette drive
4. System board