Table of Contents Read Before Use ......................1 Important Notes ........................1 Structure ............................2 Basic Function ......................3 Basic Information ........................3 Initialization ..........................4 Random Password ........................4 Normal Open ..........................5 Low Battery Alarm ........................5 Volume ............................5 9V External Battery ........................
Page 3
Register another Administrator ..................9 Register Normal User ......................10 Delete User Number ......................11 Delete Administrator Group (delete all the administrator) ......12 Delete Normal User Group (delete all the normal user) ....... 13 Supplemental Register ...................... 14 Enable Normal Open ......................15 Volume setting........................
Read Before Use Important Notes Factory setting of all new locks allows ANY verification to unlock them. One administrator must be registered on newly installed locks. Ordinary users cannot be registered until an administrator is registered. The lock is equipped with a mechanical key. Store the mechanical key in a safe place. Four alkaline AA batteries (not included) are required to power on the lock, Non-alkaline and rechargeable batteries ARE NOT RECOMMENDED.
Structure Front view Rear view Bottom view 1 Keypad Area 5 Battery Area 2 Card Detection Area 6 Reset Button 3 Keyhole 7 Battery Cover 4 Handle 8 9V Battery port P a g e...
Basic Function Basic Information Group Verification Mode Function Capacity Card Max.100 Register / Delete User, Administrator Open The Door, Access the menu Password Max.100 Card Max.100 User Open the door Password Max.100 Note: The maximum card/password capacity of lock is 100. Password must be of six digits.
Initialization After installing the lock, you must perform initialization process as explained below: 1. Press and hold the reset button, then touch the pad, keep holding the reset button until you hear "Restore to default settings, wait a moment" voice prompt. 2.
Normal Open Normal Open Mode keeps the door unlocked until a registered card, or password is validated. Low Battery Alarm When the lock has a low battery a short beep and voice prompt of "Battery is low, please replace" will be prompted". Note: Access to operation steps is not allowed in low battery status.
9V External Battery 9V external battery is used to open door when the lock is not operating through battery. Note: The battery must be 9V alkaline battery (6LR61). P a g e...
Emergency Mechanical Key The mechanical key is used to open door when the lock has an electronic malfunction. Insert the key into key hole and rotate 90° in clockwise direction. Note: Keep the mechanical key in a safe place. P a g e...
How to Use Register First Administrator Operating Steps Touch the keypad to wake up the lock Press to access the menu Enter a desired 3 digits user number, e.g. 001 Enter a six digits password twice, or swipe card. Continue to register other identifications on the same user number Enter additional verification Press to complete registration...
Register another Administrator Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to register user Press to register administrator Enter a desired 3 digits user number, e.g. 001 Enter a six digits password twice, or swipe card.
Register Normal User Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to register user Press to register administrator Enter a desired 3 digits user number, e.g. 001 Enter a six digits password twice, or swipe card.
Delete User Number Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to delete user Press to delete by user number Enter 3 digits user number require to delete Enter 3 digits user number require to delete again P a g e | 11...
Delete Administrator Group (delete all the administrator) Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to delete user Press to delete by group Press to delete administrator group press...
Delete Normal User Group (delete all the normal user) Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to delete user Press to delete by group Press to delete normal user group...
Supplemental Register (Register additional verification details for an existing user.) Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to do supplemental register Enter a desired 3 digits user number, e.g.
Enable Normal Open It will keep the door always in unlocked mode Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press to enable normal open Note: To disable normal open, please use admin card / password to unlock the door.
Volume setting Operating Steps Touch the keypad to wake up the lock Press to access the menu Verify administrator using card, or enter password and press to confirm Press0 and 1to enable volume setting Decrease volume by pressing 1, and increase volume by pressing 2, then press to confirm Note:...
Mute Function Operating Steps Touch the keypad to wake up the lock Press and then to enable mute function Note: After enabling the mute function, no key tone will be heard. To disable the mute function, touch the keypad to wake up the lock and press and #.
Quick Start Open the Door with Password Touch the keypad to Enter password, and Press the handle down wake up the lock press to confirm to open the door Open the Door with Card Touch the keypad to Swipe the registered Press the handle down wake up the lock card on the card area...