Cautions A new lock is defined as always in open mode until it is locked once by a IC S50/S70 card. Please register an authorized card, a time sync card, and a room card initially for the new lock. The lock is equipped with keys for manual unlocking. Remove the keys from the package and keep them in a safe place.
What's in Box Outdoor Unit Indoor Unit Mortise Cylinder Spindle A Spindle B Keys Studs Strike Plate and Box Hex Wrench A Screw A Screw B Screw C IC Card Hex Wrench B Note: This lock is ideal for doors with a thickness of 32 mm to 58 mm. This lock will not fit on a door that is thicker than 58 mm.
Installation Diagram Screw C Battery Cover Stud Screw C Spindle A Indoor Unit Spindle B Outdoor Unit Screw B Cylinder Screw A Screw A Strike Plate Mortise Stud Keys Installation Procedure Door Opening Direction Mortise Strike Plate Strike Plate Mortise Left Inward Right Inward Mortise...
Page 5
Mortise Strike Plate Strike Plate Mortise Left Inward Right Inward Mortise Strike Plate Strike Plate Mortise Left Outward Right Outward Person Location 6085 Mortise Note: Please install the Mortise and Strike Plate according to the above illustration. Adjust the Latch's Direction (if necessary) Adjustment of 3085 Mortise When you rotate the mortise 180 degrees, the fastener will dropdown.
Adjustment of 6085 Mortise Push Up the fastener. The latch pops up. Rotate the latch 180 degrees. Push the latch back. Drilling Holes on the Door Paste the Installation Template at the desired handle height. Mark for the holes to be drilled and drill the marked places.
Installation the Mortise Insert the mortise into the drilled hole, secure it with Screw A, and make sure the cable is towards the outdoor unit. Screw A Insert the Cylinder, then secure it with Screw B. Screw B...
Installation the Outdoor Unit Method of 3085 Mortise Install the Studs on the back of the Outdoor Unit. Insert a Spindle A into the clutch toward Outdoor Unit. Attach the Outdoor Unit to the door. Note: Please pay attention to the point of clutch, the point is at right side when right opening, the point is at left side when left opening.
Installation Indoor Unit Insert the Spindle B into the cylinder and turn it to 45°. Connect the battery cable with the mainboard. Secure the Indoor Unit with 2 Screws C by Hex Wrench A. Spindle B Hex Wrench A Screw C Install Batteries To install batteries, remove the Battery Cover with Hex Wrench B, then reinstall it.
Installation of Strike Plate and Box Make sure that the Strike Box is aligned with the latch bolt. Then, use the Installation Template to drill holes. Align the Strike Plate and Box with the drilled holes and secure them with Screw A. Unit: mm Screw A 3085 Mortise...
Test the Lock by Mechanical Key Insert one of the key and rotate it to 90° and then press the outdoor unit handle, if the latch backs up, it means exact. Note: The handle of outdoor unit is always free. Keys...
Page 12
Warning: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.