Page 1
USER MANUAL DL30B Digital Lock with Voice Guide Feature Version: 1.1 Date: July, 2017 P a g e...
Page 2
Contents Table of Contents Safety Precautions .................................... 1 Structure ....................................... 2 User Introduction ....................................3 Operation and Voice Prompt ................................ 4 Initialization ......................................4 Random Password .................................... 5 Voice Guide ......................................5 Normal Open ...................................... 6 Low Battery Alarm ..................................... 6 Volume ........................................
Page 3
Register Normal User ..................................12 Delete by User Number ................................. 14 Delete Administrator Group ................................ 16 Delete Normal User Group ................................17 Supplemental Register .................................. 18 Enable Normal Open ..................................19 Volume ........................................ 20 Mute Function ....................................21 Open the Door with Password ..............................22 Open the Door with Card ................................
Read Before Use Safety Precautions The default setting of the lock allows any password/card to unlock it. Please register at least one administrator for the newly installed lock. Without administrator, registration for any normal user is not allowed. The lock comes with mechanical keys for manual unlocking. Please keep the mechanical keys at a safe place.
Basic Functions User Introduction User Verification Mode Function Password Menu Operation, Administrator Open The Door ID Card Password Normal User Open The Door ID Card Note: 1) The maximum capacity of password or ID card is100. 2) The length of password is 6 digits. P a g e...
Operation and Voice Prompt Operation Voice Prompt Verification Succeeded “Thank you” Verification Failed “Verification Failed” Registration Succeeded “Registered” Deletion Succeed “Deleted” Registration Failed “Operation Failed” Password has already registered “This password is already used” ID Card has already registered “This card is already used” User Number has already registered “This user number is already used”...
Operation Instruction: Press the reset button, then touch the keypad to power on the lock, and hold the reset button for 5 seconds until the lock prompts the voice of “Restore to default settings, wait a moment”. After around 30 seconds, the lock prompts the voice of “completed”, and then the initialization is finished.
Normal Open Normal open mode is to keep lock always unlocked, which is fit for meeting room and some places where in or out is not restricted. Low Battery Alarm When the lock is in low battery status, it will trigger the alarm with the sound of short beep and the voice of “Battery is low, please replace”.
9V External Battery 9V external battery is used to open door when the lock is not operating through battery. Note: The battery must be 9V alkaline battery (6LR61). P a g e...
Emergency Mechanical Key The mechanical key is used to open door when the lock has an electronic malfunction. Note: Keep the mechanical key at a safe place. Insert the key into key hole and rotate 90° in clockwise direction. P a g e...
How to Use Register First Administrator Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Voice prompt "Register administrator, Press and then to access the menu enter three digits user number" Enter 3 digits user number Voice prompt "Enter card or password"...
Register Another Administrator Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to register user Start voice guide for the key of 1 and 2...
Page 14
Note: 1) Enter the password twice to register. 2) The length of password is 6 digits. When verifying administrator by password, press end. 3) The regular length of user number is 3 digits. However, it is also correct to enter 1 digit or 2 digits with the end of as the user number.
Register Normal User Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to register user Start voice guide for the key of 1 and 2...
Page 16
Note: Enter the password twice to register. 2) The length of password is 6 digits. When verifying administrator by password, press end. 3) The regular length of user number is 3 digits. However, it is also correct to enter 1 digit or 2 digits with the end of as the user number.
Delete by User Number Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to delete user...
Page 18
Note: 1) The regular length of user number is 3 digits. However, it can also be entered as 1 digit or 2 as the user number. For example, 001 is equal to 1# or 01#. digits with the end of 2) When verify administrator by password, press to end.
Delete Administrator Group Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to delete user Start voice guide for the key of 1 and 2...
Delete Normal User Group Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to delete user...
Supplemental Register Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Voice prompt “Enter three digits user Press to do supplemental register...
Enable Normal Open Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to enable normal open Voice prompt “Normal Open is enabled”...
Volume Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to access the menu Voice prompt "Verify administrator" Verify administrator by card or password Start voice guide for the key of 1 to 4 Press to enable volume setting Voice prompt “Beep”...
Mute Function Operating Steps Indication of the Lock Touch the keypad to power on the lock Keypad backlight is powered ON Press and then to enable mute function Note: 1) After enable the mute function, no sound prompt for all operations on the keypad. 2) To disable the mute function, press and then again after the keypad backlight is...
Quick Start Open the Door with Password Touch the keypad to Press the handle down Enter password, and power on the lock to open the door press to end Note: User may enter random password to prevent any person beside from observing the password.