● If you select RSY +, plus direction will be selected and 01.000 will
appear on LCD, now you can input frequency via keypad (frequency
range: 00.000~99.995).
● If you select RSY -, minus direction will be selected and 01.000 will
appear on LCD, now you can input frequency via keypad (frequency
range: 00.000~99.995).
5.Press [F] key again to finish setting mode and exit VFO mode.
Note:
The combined frequency between offset frequency and transceiver's
current working frequency must be in the range of your transceiver, if not,
your setting of offset will not value.

Reverse Function

While monitoring a repeater, the reverse function allows you to
manually check the signal strength of a station accessing the
repeater.
1.Press [V/M] key to select MR working mode.
● You should have to set offset direction and frequency in VFO firstly,
and save the setting as Memory Channel, Otherwise, you can use this
reverse function.
2.Press [F]+[5] key to switch reverse function ON/OFF.
● The receive frequency and the transmit frequency are exchanged.
●" R" appears when the function is ON.
● To switch reverse function OFF, press [F]+[5] key again, "R" indicator
will not display on LCD.
Note:
● If pressing [F]+[5] key places the transmit frequency outside the
allowable transmit frequency range, an error beep sounds when [PTT] is
pressed, and transmission is inhibited.
● If reversal would place the receive frequency outside a receive
frequency range, an error beep sounds when [PTT] is pressed. No
reversal occurs.
● Automatic repeater offset does not function while Reverse is ON.
● You can not switch Reverse ON or OFF while transmitting.
1750 Hz Tone
Some European repeaters require a 1750 Hz tone burst to be
accessed. For such European repeaters, perform the following.
1.In VFO/MR/CH mode, press [MENU] key to enter menu system.