Connection - Siemens SINUMERIK ONE NCU 1760 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1760:
Table of Contents

Advertisement

Connectable components
11.1 NX10.3/NX15.3
11.1.4

Connection

Power supply X124
Table 11-2
Note
The two "+" and "M" terminals are jumpered in the connector and not in the device. This ensures
that the supply voltage is looped through.
The current consumption increases by the current consumption of DRIVE-CLiQ and the digital
outputs.
When using external power supplies (e.g. SITOP), the ground potential of the power supply
must be connected with the protective ground connection of the system (PELV).
Table 11-3
Characteristics
Connector type
Connectable cable types and conductor cross-sections
● Rigid
● Flexible
● Flexible, with end sleeve without plastic sleeve
● Flexible, with end sleeve with plastic sleeve
● AWG / kcmil
Stripped length
Tool
Tightening torque
Max. current carrying capacity, incl. loop-through
Max. cable length
98
Pin assignment for X124
Pin
Function
+/-
24 VDC power supply (20.4 V - 28.8 V)
+/-
M
Ground
M
Cable specification for X124
Version
4-pin screw-type terminal
● 0.2 mm² to 2.5 mm²
● 0.2 mm² to 2.5 mm²
● 0.2 mm² to 2.5 mm²
● 0.2 mm² to 1.5 mm²
● 16 to 14
6-7 mm
Screwdriver 0.5 x 3 mm (M2.5)
0.4 to 0.5 Nm
20 A (15 A according to UL/CSA)
10 m
Equipment Manual, 02/2020, A5E45627861B AB
NCU 1760