Component Locations; Battery Disconnect Switch; Battery Status Led - Generac Power Systems PWRcell 3 Installation Manual

Table of Contents

Advertisement

General Information

Component Locations

OFF
ON
A
B
C
Figure 2-4. Component Locations
A

Battery Disconnect Switch

B

Battery Status LED

C
Intake Filter
D
Front Cover
E
Exhaust Vent
10
Battery Disconnect Switch
E
See
Figure
disconnects the battery string from the battery monitoring
system (BMS) electronics.
NOTE: Battery Disconnect can be locked in the OFF
position if required.
D
NOTE: Turn Battery Disconnect OFF whenever system
will be powered down and left inactive for an extended
period of time.
Battery Status LED
See
Figure
(B) communicates the Generac PWRcell Battery status.
LED State
Green, 3 sec
solid at power up
0009890
Red, 3 sec solid
at power up
Red/green,
alternating
Green, solid
Green, strobe
Green, flashing
Orange, solid
Orange, strobe
Red, strobe
Red, flashing
DANGER
Electrocution. Initiate a system-wide safety shutdown
and turn PWRcell Disconnect Switch OFF on all
connected batteries before performing service. Failure
to do so will result in death, serious injury, equipment
and property damage.
2-4.
Battery
Disconnect
2-4.
The color and strobing interval of LED
Table 2-1. Battery Status LED
Interpretation (strobe interval)
Enabled, operation starting
Disabled
Initializing, connecting battery and
REbus, system energizing
Enabled, charging
Enabled, standby (3 sec)
Enabled, discharging
Waiting
Asleep (8 sec)
Disabled (3 sec)
Error state
Installation Manual for Generac PWRcell Battery
(000600)