Download Print this page

Federal Signal Corporation CUDA TRIOPTIC 351011 Series Instruction Sheet page 2

Advertisement

CUDAMOD1 LIGHT
HEAD ASSEMBLY
LEFT SIDE CABLE ENTRY
(AS SUPPLIED)
installer for cable entry in the right side, the left rear, or the
right rear. Vertically mounted units may have the cable routed
from the side end cap (as supplied) or from the rear (installer
modified). From a horizontal orientation, the top, bottom and
rear surfaces of the unit are available for mounting. The top
and bottom surfaces have one mounting bolt channel and the
rear surface has two mounting bolt channels (see figure 2).
Choose the mounting channel that best suits your application.
After determining the cable entry and mounting orienta-
tion, follow the appropriate instructions.
1.
Horizontal Mount-Left Side End Cap Cable Entry,
or Vertical Mount-End Cap Cable Entry (unit as
supplied).
See figure 2. Remove the end cap and gasket from the
side of the unit without the power cable. Slide in the two #8-32
x 1/2" hex head machine screws into the channel desired.
Replace the gasket and end cap using the two flat head screws.
SCREWS, #8-32 x 1/2"
HEX HEAD MACHINE (2)
TOP CHANNEL
BOTTOM
CHANNEL
BOTTOM DRAINAGE
HOLES
Figure 1.
REAR CHANNEL
SLIDE MACHINE SCREWS
INTO DESIRED CHANNEL
END CAP
290A4681
Figure 2.
Insure the end cap screws are properly tightened for a tight
seal.
2.
Horizontal Mount-Left Rear Cable Entry, or
Vertical Mount-Rear Cable Entry (installer
modified).
See figure 3. Remove the end cap and gasket from the
side of the unit with the power cable. Remove the end cap and
gasket from end of the grommet/cabling. Remove the left rear
plug from the housing and install it into the removed end cap.
Route the cabling towards the left rear of the unit sliding the
grommet into the slot where the plug was installed. Before re-
attaching the end cap/gasket, slide in the two #8-32 x 1/2" hex
head machine screws into the desired mounting channel.
Replace the gasket and end cap using the two flat head screws.
Insure the end cap screws are properly tightened for a tight
seal.
3.
Horizontal Mount-Right Side End Cap Cable
Entry (installer modified).
290A4680
See figure 4. Remove the #8-32 screws and lock
washers from the rear of the unit. Remove the screws which
secure the end caps and gaskets in place. Remove both the
right and left plugs from the unit. Slowly slide the left side
cable/end cap/gasket/circuit board assembly out of the housing.
Slide the assembly into the opposite side of the unit. Install the
#8-32 screws/lock washers to lock the assembly into the
housing. Before replacing the end cap/gaskets, slide in the two
#8-32 x 1/2" hex head machine screws into the desired mount-
ing channel. Install the two plugs in the rear of the housing.
Replace the gaskets and end caps using the four flat head
screws. Insure the end cap screws are properly tightened for a
tight seal at both ends.
4.
Horizontal Mount-Right Rear Cable Entry
(installer modified).
Remove the #8-32 screws and lock washers from the
rear of the unit. Remove the screws which secure the end caps
and gaskets in place. Remove both the right and left rear plugs
from the unit. Slowly slide the left side cable/end cap/gasket/
SCREWS, #8-32 x 1/2"
HEX HEAD MACHINE (2)
GASKET
LEFT REAR
PLUG
ROUTE CABLE /GROMMET
REMOVED FROM END CAP
TO LEFT REAR OF UNIT.
-2-
TOP CHANNEL
SLIDE MACHINE SCREWS
INTO DESIRED CHANNEL
GASKET
GROMMET
GROMMET
Figure 3.
END CAP
FLAT HEAD
SCREWS
LEFT REAR
PLUG
290A4682

Advertisement

loading