Printed in U.S.A.
SAFETY MESSAGE TO INSTALLERS AND USERS
People's lives depend on your safe installation
of our products. It is important to read, under-
stand and follow all instructions shipped with
the products. In addition, listed below are some
other important safety instructions and precau-
tions you should follow:
To properly install this light, you must have
a good understanding of automotive
systems, along with proficiency in the
installation and use of safety warning
equipment.
DO NOT install equipment or route wiring
in the deployment path of an air bag.
When drilling into a vehicle structure, be
sure that both sides of the surface are clear
of anything that could be damaged.
In order for the light to function properly, a
separate ground connection must be made.
If practical, it should be connected to the
negative battery terminal. At a minimum, it
may be attached to a solid metal body or
chassis part that will provide an effective
ground path as long as the light system is to
be used.
Locate light control so the VEHICLE and
CONTROL can be operated safely under all
driving conditions.
Do not attempt to activate or deactivate
light control while driving in a hazardous
situation.
You should frequently inspect the light to
ensure that it is operating properly and
that it is securely attached to the vehicle.
This product contains high intensity LED
devices. To prevent eye damage, DO NOT
stare into the light beam at close range.
The light should be frequently inspected to
ensure that it is operating properly and
that it is securely attached to the vehicle.
File these instructions in a safe place and
refer to them when maintaining and/or
reinstalling the product.
Failure to follow all safety precautions and instruc-
tions may result in property damage, serious injury, or
death to you or others.
INSTRUCTION SHEET FOR CUDA TRIOPTIC™
MODEL 351011 SERIES
WARNING
A.
GENERAL.
The Cuda TriOptic Model 351011 is an LED light head
designed for use in conjunction with all Federal Signal switch
controllers. This light head is designed for mounting on a
vehicle's interior, exterior, or on a motorcycle. The housing is
comprised of an extruded aluminum profile with a front high-
impact polycarbonate protective lens. The unit is supplied with
mounting hardware and a five-foot cable. This unit has an
operating temperature of -30°C to +65°C (-22°F to +149°F). It
may be mounted in the horizontal, or vertical, position with the
cabling exiting from either side or the rear. The physical
dimensions of this unit are 3.8-inches long by 1.5-inches wide
by 1.75-inches high. End caps and the front lens cover are
compression sealed to the extruded housing by means of Buna-
N gasketing. The unit also features stainless steel hex machine
screws and kepsnuts for the channels on the top, bottom and
rear of the housing. The Cuda TriOptic is programmed with
eight flash patterns selectable by a control lead. The light head
can also be user-configured to be controlled by an external
flashing device.
B.
INSTALLATION.
This product is intended for supplemental
warning and for use in conjunction with an
approved primary warning light system.
Consult local codes and regulations to deter-
mine if the power supply/ light head combina-
tion complies with the horizontal or vertical
mount positioning desired in your application.
When installing equipment inside air bag
equipped vehicles, the installer MUST ensure
that the equipment is installed ONLY in areas
recommended by the vehicle manufacturer.
Failure to observe this warning will reduce the
effectiveness of the air bag, damage the air bag,
or potentially damage or dislodge the equip-
ment, causing serious injury or death to you or
others.
For adequate condensate drainage, a horizontally
mounted unit MUST be mounted with the two drain
holes facing down (see figure 1). For vertical mount-
ing, the drain holes are located conveniently on either
end of the housing such that the cabling may be
routed from top or bottom.
Determine which side of the unit will be attached to the
mounting surface and which direction the power cable enters
the unit.
The unit is supplied with the power cable entering the left
side. Horizontally mounted units may be modified by the
WARNING
WARNING
NOTE

Advertisement

loading

Summary of Contents for Federal Signal Corporation CUDA TRIOPTIC 351011 Series

  • Page 1 2561895B REV. B 904 Printed in U.S.A. INSTRUCTION SHEET FOR CUDA TRIOPTIC™ MODEL 351011 SERIES SAFETY MESSAGE TO INSTALLERS AND USERS GENERAL. The Cuda TriOptic Model 351011 is an LED light head WARNING designed for use in conjunction with all Federal Signal switch controllers.
  • Page 2 Insure the end cap screws are properly tightened for a tight seal. CUDAMOD1 LIGHT HEAD ASSEMBLY Horizontal Mount-Left Rear Cable Entry, or Vertical Mount-Rear Cable Entry (installer modified). See figure 3. Remove the end cap and gasket from the side of the unit with the power cable. Remove the end cap and gasket from end of the grommet/cabling.
  • Page 3 CAUTION SCREWS, #8-32 x 1/2" HEX HEAD MACHINE (2) (SLIDE MACHINE SCREWS INTO DESIRED CHANNEL) After prolonged operation, the unit dissipates heat and can cause burns. Do not hold the unit in your hands for extended periods of time. Do not touch the TOP CHANNEL unit during, or shortly after, operation.
  • Page 4 Replacement Parts. This unit contains NO user replaceable components. Consult the factory regarding warranty repairs/replacement issues. Manufactured by: Federal Signal Corporation Emergency Products Group 2645 Federal Signal Drive University Park, Illinois 60466 1-800-433-9132 Email: empserviceinfo@fedsig.com Copyright 2004 Federal Signal Corporation...