Summary of Contents for Zip HydroTap G4 IS Industrial Series
Page 1
The Worlds most advanced Drinking Water Appliance Model : IS & IT Industrial VENTILATION IS ESSENTIAL READ SECTION 1 ‘VENTILATION’ BEFORE YOU START Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 2
These standalone taps are directly compatible with the 3 button side touch G4 Command-Centre 2 button top touch Boiling chilled Command-Centre for industrial models Command-Centre Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
• Activate / enable the booster (if fitted). • Where applicable, programme the Command Centre to suit the customer’s requirements. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
(factory set to 5-9°C). These units are NOT designed to be used as sanitary fixtures. The Zip HydroTap G4 models which dispense boiling water are fitted with a tap mounted safety lock. In addition, there are various energy saving options accessible via the main menu. The system is equipped with a self-calibrating program which caters for altitude adjustment.
9, for the weight of the product. Airflow The Zip HydroTap G4 operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation must be provided. The system will operate satisfactorily only if the recommended air gaps are provided. See Section 1 'Ventilation', page 13, for correct installation to prevent overheating.
WARNINGS AND REGULATORY INFORMATION Warnings • The Zip HydroTap G4 must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1Ω. • All installation and service work must be completed by trained and suitably qualified tradespeople.
BCH240/175G4 CLAMP AV160/125G4 required. (One GPO is for the Zip HydroTap and the other for the Booster heater). NOTE: feed each of the three tubes and NOTE: Check the cable lengths and outlet positions before proceeding. electrical cable evenly in between the legs of...
Chilled water will continue to be dispensed after the rated capacity has been used, although this may affect the dispense temperature. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Technical specification, page 9 for dimensions. Make allowance for a booster if required. See sections 3 page 16 for installation instructions. • For Zip HydroTap G4 models without booster, 1 x user easy accessible 220-240V AC 13A socket will be required.
Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory (see Major components and accessories, page 8).
Supplied with tap Long series M6 x 30 13mm Not supplied M6 nut M6 x 40 24mm 19mm Not supplied Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
A clearance envelope around all Command Centres must be provided to allow adequate ventilation for the safe and effective use of the HydroTap G4 system. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Position vent grille on either the kick board or the cupboard ends Important See section 5 Command-Centre installation, page 26 Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 15
Position a vent grille in the cupboard end or Inlet grille should be inlet grille on the baseboard fitted on baseboard Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
The booster system is a compact electronically controlled auxiliary water heater. It is intended to provide pre-heating of water before it enters the Zip HydroTap G4 boiling tank. If the booster is used the boiling water output will be increased.
Pull out template THIS TEMPLATE IS NOT REQUIRED FOR INDUSTRIAL TOP TOUCH TAPS Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 18
ENSURE TAP SPOUT POSITION CORRESPONDS TO THE DIRECTION PRESCRIBED ABOVE • ENSURE THAT NO SCALING HAS TAKEN PLACE DURING PRINTING Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 19
ENSURE TAP SPOUT POSITION CORRESPONDS TO THE DIRECTION PRESCRIBED ABOVE • ENSURE THAT NO SCALING HAS TAKEN PLACE DURING PRINTING Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 20
Pull out template Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Tilt forward Lift up Take care not to break the Release lower clips when removing or installing the booster Install Attach Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Page 22
Note 1 This appliance is intended for use with the Zip HydroTap G4 Command Centre Note 2 Water connections must be pointing vertically upwards. Note 3 The booster unit should be installed as close as possible to the Zip HydroTap G4 as the 500mm connection hoses cannot be lengthened.
• Zip scale filter cartridge installation and operating instructions 2017, supplied with the filter cartridge. • Zip scale filter head installation and operating instructions 2017, supplied with the filter head. Flush valve Outlet (To Bypass in)
Page 24
Water block installation 4.3 Description • The Water Block is designed to be installed upstream of any Zip product and associated pipe-work to minimise the potential for water leakage in the event of a system malfunction. • The Water Block is ideal for limiting potential leakage and resulting water damage from water heaters, water chillers etc.
The reset device (see Fig.2) may be fitted to avoid disconnection. This allows the Water Block to be reset by operating the lever in the direction shown in Fig.2. • In the event of persistent tripping contact Zip for advice on 0345 6 005 005. 4.8 Maintenance •...
Isolation valves are not supplied. • Braided hose for mains water supply 90º bend Connector + strainer Connect to HydroTap Command Centre Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
No external filter installed - Select position A Rotate 90° only Rotate 90° only External filter installed - Select position B Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Also ensure that the (factory fitted) bypass tube assembly is fitted in place if the booster and / or external filter are not used. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Once the filter flush is finished, Turn the stop cock off NEXT then press [STOP] to end filter flush mode. • Press [NEXT] for the boiling calibration screen. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
• Press [Menu] button for main menu. • Press [Service]. • Enter the current password. (Please contact your local service centre for details). Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
• Check that the water is clear, and that there are no bubbles or foam present in the dispensed water. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk...
Call Zip Service Flow Sensor Fault Internal fault Call Zip Service Call an electrician, a plumber, or Zip on 0345 6 005 005 for assistance, service, spare parts or enquiries. Installation instructions Technical support 802742UK V4.00 Sept 2018 - Zip HydroTap Industrial...
Within each of the European Union member countries, provisions have been made for collection and recycling of unwanted electrical and electronic equipment. In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service on 0345 6 005 005 for advice.
Furthermore this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the...