HP ProLiant ML150 Generation 2 Maintenance And Service Manual
HP ProLiant ML150 Generation 2 Maintenance And Service Manual

HP ProLiant ML150 Generation 2 Maintenance And Service Manual

Table of Contents

Advertisement

Quick Links

HP ProLiant ML150 Generation 2 Server
Maintenance and Service Guide
June 2005 (Third Edition)
Part Number 368148-003
HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/16/05 8:51 AM

Advertisement

Table of Contents
loading

Summary of Contents for HP ProLiant ML150 Generation 2

  • Page 1 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide June 2005 (Third Edition) Part Number 368148-003 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/16/05 8:51 AM...
  • Page 2 The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Memory Module Guidelines........................2-39 Memory Modules ............................ 2-41 Processors and Heatsinks ........................2-42 System Board ............................2-47 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/16/05 8:51 AM...
  • Page 4 Physical and Operating Specifications System Unit..............................5-2 Memory..............................5-3 1.44-MB Diskette Drive..........................5-3 IDE CD-ROM Drive..........................5-4 Wide Ultra3 SCSI Hard Drives........................5-5 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/16/05 8:51 AM...
  • Page 5 Contents SATA Hard Drives ............................ 5-5 LAN-on-Motherboard (LOM)........................5-6 Index HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/16/05 8:51 AM...
  • Page 6: Illustrated Parts Catalog

    Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts lists for the HP ProLiant ML150 Generation 2 (G2) server. Refer to Table 1-1 for the names of referenced spare parts. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide...
  • Page 7: Exploded View

    Power supply 372783-001 Rear system fan 372787-001 Rear system fan holder 374895-001 System board 373275-001 continued HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:17 PM...
  • Page 8 373456-001 SCSI non-hot-plug hard drive cage 372659-001 SCSI non-hot-plug hard drive – 36GB 15K continued HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:17 PM...
  • Page 9 EMI shield for the SCSI non-hot-plug model 373383-001 Rail kit 373015-001 Hardware kit 373464-001 Return kit Not shown HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:17 PM...
  • Page 10: Removal And Replacement Procedures

    HP ProLiant ML150 G2 server. To service the server, a T-15 Torx screwdriver may be needed. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 11: Electrostatic Discharge Information

    Always place drives with the Printed Circuit Board (PCB) assembly-side down. • Use conductive field service tools. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 12: Symbols On Equipment

    Weight in lb manual material handling. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 13: Preparation Procedures

    CAUTION: The server must always be operated with system unit covers on. Proper cooling is not achieved when the system unit covers are removed. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 14 4. Disconnect the AC power cord from the AC outlet, and then from the server. 5. Disconnect all external peripheral devices from the server. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 15: Bezel Door

    2. If the bezel lock is locked, unlock the bezel door using the included key. Figure 2-1: Unlocking the bezel door HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 16 To remove the EMI shield, remove the four screws securing the shield to the bezel door. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 17: Access Panel

    Figure 2-3: Removing the access panel To replace the access panel, reverse steps 2 through 4. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 18: Cable Routing Diagrams

    IDE CD-ROM Drive Signal Cable Figure 2-4: IDE CD-ROM drive signal cable routing HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 19: Diskette Drive Signal Cable

    Figure 2-5: Diskette drive signal cable routing SCSI Hot-Plug Hard Drive Cable Figure 2-6: SCSI hot-plug hard drive cable routing 2-10 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 20: Scsi Non-Hot-Plug Hard Drive Cable

    Figure 2-7: SCSI non-hot-plug hard drive cable routing SATA Hot-Plug Hard Drive Cable Figure 2-8: SATA hot-plug hard drive cable routing HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-11 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 21 J516. For detailed information on how to install the card, refer to the 6-Port SATA RAID controller User Guide. 2-12 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 22: System Fan Modules

    NOTE: Front system fan cable connection shown for clarity (2). Figure 2-9: Disconnecting the fan cables from the system board HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-13 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 23 Figure 2-11: Removing the rear system fan holder To replace the rear system fan module, reverse steps 2 through 8. 2-14 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 24 When installing the fan module, a click sound indicates that the fan module is secured to the front panel. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-15 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 25: Drive Bay Configuration

    SCSI hot-plug hard drive bays SCSI non-hot-plug hard drive bays SATA hot-plug hard drive bays 2-16 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 26: Boot Priority

    8. (reserved for additional boot devices) NOTE: The boot order can be changed using the server’s BIOS Setup Utility. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-17 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 27: Flexible Diskette Drive

    5. Hold the drive by its sides and gently slide the drive out of the drive bay. Figure 2-15: Removing the flexible diskette drive 2-18 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 28 Figure 2-17: Attaching the rails to the flexible diskette drive HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-19 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 29: Cd-Rom Drive

    5. Hold the drive by its sides and gently slide the drive out of the drive bay. Figure 2-18: Removing the CD-ROM drive 2-20 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 30 Figure 2-20: Attaching the rails to the CD-ROM drive HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-21 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 31: Scsi Hot-Plug Hard Drive Blank Carrier

    To replace the SCSI hot-plug hard drive blank carrier, reverse steps 1 through 2. 2-22 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 32: Scsi Hot-Plug Hard Drive

    4. Use your hand to support the bottom of the hard drive carrier while you slowly pull the carrier straight out. Do not allow the carrier to fall. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-23 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 33 Closing the ejector handle engages the hard drive with the electrical connector in the hot- plug hard drive cage and seats the hard drive. 2-24 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 34: Scsi Hot-Plug Hard Drive Cage

    8. Remove the back plane from the hard drive cage and take it away from the chassis (2). Figure 2-24: Removing the SCSI back plane HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-25 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 35 When installing the hard drive cage in the chassis, be sure that the hard drive cage is seated properly on the supporter. 2-26 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 36: Scsi Non-Hot-Plug Hard Drive

    Do not allow the hard drive to fall. Figure 2-26: Removing the SCSI non-hot-plug hard drive HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-27 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 37 Verify that the hard drive is flush with the other hard drives. If the hard drive is not flush, it is not seated properly in the drive bay. 2-28 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 38: Scsi Non-Hot-Plug Hard Drive Cage

    When installing the hard drive cage in the chassis, be sure that the hard drive cage is seated properly on the supporter. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-29 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 39: Sata Hot-Plug Hard Drive Blank Carrier

    To replace the SATA hot-plug hard drive blank carrier, reverse steps 1 through 3. 2-30 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 40: Sata Hot-Plug-Hard Drive

    4. Use your hand to support the bottom of the hard drive carrier while you slowly pull the carrier straight out. Do not allow the carrier to fall. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-31 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 41 Closing the ejector handle engages the hard drive with the electrical connector in the hot- plug hard drive cage and seats the hard drive. 2-32 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 42: Sata Hot-Plug Hard Drive Cage

    8. Remove the back plane from the hard drive cage and take it away from the chassis (2). Figure 2-33: Removing the SATA back plane HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-33 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 43 When installing the hard drive cage in the chassis, be sure that the hard drive cage is seated properly on the supporter. 2-34 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 44: Expansion Slots

    Do not insert an add-on card with an RJ-45 connector into PCI-X slot 1. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-35 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 45: Expansion Board

    Rotate the bracket outwards to detach it from the chassis. Figure 2-36: Removing the IO locking bracket 2-36 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 46 6. Replace the IO locking bracket. To replace an expansion board, reverse steps 2 through 6. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-37 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 47: Expansion Board Holder

    Figure 2-38: Removing the expansion board holder To replace the expansion board, reverse steps 1 through 4. 2-38 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 48: Memory Module Guidelines

    Item Description DIMM slot 1 DIMM slot 2 DIMM slot 3 DIMM slot 4 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-39 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 49 DIMM sizes supported are 512 MB, 1 GB, and 2 GB, allowing a total of 8 GB maximum system memory (2 GB in each of the 4 DIMM slots). • DIMM sizes may be mixed on the system board. HP recommends starting at slot 1 and filling the slots in order with the largest size first. •...
  • Page 50: Memory Modules

    Figure 2-40: Removing a memory module To replace a memory module, reverse steps 2 through 4. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-41 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 51: Processors And Heatsinks

    (earthed) before beginning any installation procedure. Refer to “Electrostatic Discharge Information” earlier in this chapter. 2-42 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 52 7. Lift the heatsink away from the processor and out of the server. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-43 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 53 9. Grasp the processor by its edges, lift it out of the socket (2), and place it on a static- dissipating work surface or into an anti-static bag. Figure 2-43: Removing the processor 2-44 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 54 CAUTION: To prevent possible server malfunction, be sure to completely close the ZIF lever. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-45 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 55 9. Carefully lift the server back to its upright position. 10. Reconnect all power cords. 2-46 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 56: System Board

    Figure 2-46: Removing the system board To replace the system board, reverse steps 2 through 10. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-47 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 57: System Battery

    2. Remove the access panel. Refer to “Access Panel” earlier in this chapter. 3. Locate the battery on the system board. 2-48 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 58 IMPORTANT: The battery should be installed with the positive polarity (+ side) positioned up. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-49 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 59: Power Supply

    Figure 2-48: Removing the power supply To replace the power supply, reverse steps 2 through 8. 2-50 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 60: Stands

    Figure 2-49: Removing the stands from the chassis To replace the stands, reverse steps 2 through 4. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 2-51 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM...
  • Page 61: Diagnostic Tools And Setup Utilities

    Password checksum bad - Passwords cleared 0260 Extend error System timer error 0270 Extend error Real time clock error continued HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 62 Warning! BIOS detect failed CPU fans or CPU fans not connected. Please check CPU fans. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 63: Bios Setup Utility

    1. Power up the server and monitor. 2. Start the BIOS Setup Utility by pressing the F10 key on the HP logo screen. Using the Setup Screens Online help explains the settings displayed on the BIOS Setup Utility screens. Instructions are also provided for navigating between the screens and entering or changing the setup data.
  • Page 64: Menu Bar

    System Memory – Display the system memory information. • Extended Memory – Display the extended memory information. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 65 IPMI – Configure the Intelligent Platform Management Interface (IPMI) settings. • Asset Tag – Allow you to enter the asset tag. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 66 BIOS Setup Utility. In the confirmation pop-up menu, select Yes and press the Enter key. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 67 After Power Failure – Set the mode of operation if an AC power failure occurs. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 68 Figure 3-6: Boot menu of the BIOS Setup Utility Use this menu to configure the boot priority. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 69 Discard Changes – Discard any changes you have made. • Save Changes – Save the changes you have made. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 70: Bios Update

    1. Insert one blank, formatted 3.5” diskette into the flexible diskette drive of a PC running Microsoft Windows. 2. Insert the HP ProLiant ML150 G2 Server Support CD in the CD-ROM drive of the above 3. Click the desired operating system from the System Support Software list in the navigation bar.
  • Page 71: Scsi Configuration Utility

    Diagnostic Tools and Setup Utilities SCSI Configuration Utility The HP server uses the SCSISelect Utility to verify or modify the SCSI controller settings for the devices connected to the system board. If you need to verify or modify SCSI controller settings, or if you need to low-level format SCSI disks or verify SCSI disk media, run the SCSISelect Utility.
  • Page 72: Exiting Scsiselect

    To restore the original SCSISelect default settings, press the F6 key from the main SCSISelect screen. 3-12 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 73: Configuring Scsiselect Settings

    SCSI host bus adapter. If only one SCSI device is connected, changing the setting to No results in slightly better performance. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 3-13 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 74 Play. The setting can be either enabled or disabled if your system is not Plug-and- Play. 3-14 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 75: Using Scsi Disk Utilities

    — BIOS Support for Bootable CD-ROM (Default: Enabled) When set to Enabled, the SCSI host bus adapter BIOS allows the HP server to boot from a CD-ROM drive. Using SCSI Disk Utilities 1. Select SCSI Disk Utilities from the menu that displays after starting SCSISelect.
  • Page 76: Using The Taped Based One Button Disaster Recovery

    5. A message displays indicating that OBDR support is enabled. Press any key to continue. Adaptec RAID Configuration Utility The HP server uses the Adaptec RAID Configuration (ARC) Utility to verify or modify the SATA controller settings for the devices connected to the system board. If you need to verify or modify SATA controller settings, or if you need to low-level format SATA disks or verify SATA disk media, run the ARC Utility.
  • Page 77: Exiting The Arc Utility

    To restore the original default settings of the ARC Utility, press the F6 key from the utility’s main screen. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 3-17 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 78: Using Acu

    3. From the ACU main menu, select Initialize Drives and press the Enter key. 4. Select the disk you wish to initialize and press the Insert key. 3-18 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 79 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 3-19 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 80 3. From the ACU main menu, select Manage Arrays and press the Enter key. 3-20 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 81: Using The Disk Utilities

    2. From the ARC menu, select Disk Utilities and press the Enter key. 3. Select the desired disk and press the Enter key. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 3-21 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 82 — Verify Disk Media Allow you to scan the media of a disk drive for defects. 3-22 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 83: Connectors, Jumpers, And Leds

    LED locations on the front panel, rear panel, system board and hard drives for the HP ProLiant ML150 G2 server. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 84: Connectors And Components

    Thumbscrews for detachable access panel Monitor port (blue) Power supply unit fan USB 2.0 ports (black) System fan HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 85: System Board Components

    IDE channel UDMA-33 PCI slot 2 (64-bit PCI-X) BIOS flash ROM PCI slot 3 (64-bit PCI-X) continued HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 86 Broadcom GbE LAN chipset PS/2 mouse port (green) DIMM slot 4 PS/2 keyboard port (purple) DIMM slot 3 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 87: Jumpers

    Figure 4-3: System configuration jumper settings Table 4-3: System Configuration Jumper Settings Jumper Position Description Normal Clear CMOS HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 88: Clearing System Configuration Settings

    5. Replace the access panel. 6. Power up the server. 7. Reset all system configuration settings. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 89: Leds

    Powers down the server. The following system status LEDs are explained: • Power status • Hard drive status HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 90 CAUTION: When the power indicator is green, it is unsafe to remove AC power from the system without performing a proper shutdown of the operating system. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 91: Hot-Plug Hard Drive Leds

    Disk spinning up or “hung” - I/O activity • Amber (flashing): predictive failure • Amber (solid): hard drive failure HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 92: Network Interface Controller (Nic) Leds

    Refer to the HP Servers Troubleshooting Guide found on the HP website for more information on troubleshooting network controller problems. 4-10 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 93 Note: The 1000 Mbps LAN link or activity is shown when both the green and amber LEDs are on or flashing. HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide 4-11 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 94: Physical And Operating Specifications

    IDE CD-ROM drive • Wide Ultra3 SCSI hard drives • SATA hard drives • LAN-on-Motherboard (LOM) HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 95: System Unit

    6.2 NPEL (BELS)/45 AVERAGE SPL (dba) Operating (random seeks to hard drives) 6.8 NPEL (BELS)/49 AVERAGE SPL (dba) HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 96: Memory

    174 ms/94 ms Settling time 15 ms Latency average 100 ms Cylinders (high/low) 80/80 Read/write heads HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 97: Ide Cd-Rom Drive

    Stop time <4s Operating conditions Temperature 5°C to 45°C (41°F to 113°F) Humidity 10% to 80% HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 98: Wide Ultra3 Scsi Hard Drives

    5°C to 55°C 5°C to 55°C Temperature (41°F to 131°F) (41°F to 131°F) (41°F to 131°F) HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 99: Lan-On-Motherboard (Lom)

    Network transfer rate 10/100/1000 Mbps Connector RJ-45 I/O address and interrupt Plug and Play PCI HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:18 PM...
  • Page 100 2-36 handling components 2-39 replacing 2-37 handling memory modules 2-39 expansion board holder HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide Index-1 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:20 PM...
  • Page 101 4-8 SATA hot-plug hard drive cable – green 1-4 hot-plug hard drives 4-9 Index-2 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:20 PM...
  • Page 102 1-3 SCSI hot-plug hard drive cable routing 2-10 rear panel components 4-2 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide Index-3 HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:20 PM...
  • Page 103 2-2 jumper 4-5 part number 1-2 removing 2-47 system configuration jumper Index-4 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 4/19/05 5:20 PM...

Table of Contents