Omron MicroHAWK F320-F User Manual page 67

Smart camera
Table of Contents

Advertisement

2 System Components
Expected Power and Ground Connections for Proper Operation
Grounding Notes
• Ensure that mounting bracket "Earth" is at the same potential as power source "Earth".
• Supply "Return" and "Earth" ground must be stable, low-impedance reference points.
• "2-Terminal Power Supply" must still provide an "Earth" connection to the imager.
• "Signal Ground" can be used for communications and/or discrete signal ground reference. It must not
be used as Power Ground or Earth Ground.
Power Requirements
Refer to this table when determining the power requirements for your camera.
Power Supply Voltage
F320-F
5 VDC +/- 5%
F330-F
Source: 44-57 VDC IEEE802.3af POE
F420-F
5 VDC +/- 5%
F430-F
5 to 30.0 VDC, 200 mV p-p max ripple
2-32
Current Consumption
450 mA at 5 VDC (max.)
Max Current: 0.090 A
650 mA at 5 VDC (max.)
0.18 A at 24 VDC (max.)
MicroHAWK F320-F / F330-F / F420-F / F430-F Smart Camera User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microhawk f330-fMicrohawk f420-fMicrohawk f430-f

Table of Contents