9. Technical data

9. Technical data
INSULATION GROUP:
AMBIENT TEMPERATURE:
STORAGE TEMPERATURE:
HUMIDITY CLASS:
ALTITUDE RATING:
MECHANICAL STRESSING:
PACKAGING SYSTEM:
DIMENSIONS:
WEIGHT:
CURRENT DRAIN:

10. Connector assignment of the interfaces

10.1. Serial interface X5

X5 (9-pin Sub D socket connector)
Pin
Designation
1
----
2
TxD
PRFTR +
3
RTS
4
5
M5EXT
6
P5EXT
7
RxD
8
PRFTR -
RTS
9
6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
A acc. to VDE 0110 Paragraph 13 Group 2 at 24 V DC,
15 V DC, 5 V DC
0 to +55 degrees C for self-cooling
-40 to + 70 degrees C
F acc. to DIN 40040
S acc. to DIN 40040
Mounted in stationary but not necessarily vibration-free
equipment
Installed in the slot in the CS7 subrack
184 * 65 mm
0.5 kg
P5:
0.7 A
P15:
10 mA
N15:
10 mA
Explanation
----
Receive signal, monitor
Receive- and send signal +
Ready to send
External ground
P5 external
Send signal, monitor
receive- and send signal -
Ready to send