idi ilex 55 Operator's Manual

idi ilex 55 Operator's Manual

For units using msv2 video signal router
Hide thumbs Also See for ilex 55:

Advertisement

Quick Links

Operator Manual
For units using MSV2 video signal router
The text of this manual was originally written, approved and published by the manufacturer in English.
Made in the USA
L280-0975 REV A

Advertisement

Table of Contents
loading

Summary of Contents for idi ilex 55

  • Page 1 Operator Manual For units using MSV2 video signal router The text of this manual was originally written, approved and published by the manufacturer in English. Made in the USA L280-0975 REV A...
  • Page 2 For technical assistance, call IDI at (978) 829-0009 or send fax to (978) 829-0027. Be prepared to give the complete model and serial number found on the data plate on the rear of the ilex55 base at the time of contact.
  • Page 3: Table Of Contents

    ilex Operator Manual Table of Contents Symbol Identification ......................1 Intended Use ........................... 3 Safety............................3 Safety Hazards ........................4 EMC (Electromagnetic Compatibility) Statement ..............5 Basic Setup Instructions ......................6 Electronics Installation........................ 6 Moving and Positioning ......................7 Instructions for Operation ....................8 System Components Ilex55 ......................
  • Page 4: Symbol Identification

    Operator Manual ilex Symbol Identification Attention! Consult accompanying documents. Failure to follow these instructions could cause serious personal injury or damage to equipment. Read the Manual SGS North America, Inc. Testing Service. The system was tested and found to be in compliance with the requirements of all relevant directives and standards in effect within the European Union at the time of manufacture.
  • Page 5 Operator Manual ilex Emergency Stop Switch - Stops elevation motion. Maximum allowable Weight Limits. Protective Ground. This is the common tie point between the AC cord ground, frame ground, and controller ground. For safety and proper function of equipment, connect power cord to a properly grounded outlet.
  • Page 6: Intended Use

    Comments and questions regarding safety should be addressed to: Customer Support Image Diagnostics, Inc. 310 Authority Drive Fitchburg, MA 01420 USA Or call IDI at (978) 829-0009 or Toll Free (877) 304-5434. The fax number for IDI is (978) 829-0027. L280-0975 REV A www.imagediagnostics.com Page 3...
  • Page 7: Safety Hazards

    Operator Manual ilex Safety Hazards CAUTION! Do NOT store liquids above any electrical devices. WARNING! Do NOT jump any curbs or steps over 3/8” (10mm) in height with this equipment. Approach all obstacles slowly. Operator must use a ramp to allow the casters to roll up and over the vertical edge for over 3/8”...
  • Page 8: Emc (Electromagnetic Compatibility) Statement

    Operator Manual ilex EMC (Electromagnetic Compatibility) Statement This equipment may generate and use radio frequency energy. The equipment must be installed and used according to this manual in order to avoid radio frequency interference. Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment including the ilex55.
  • Page 9: Basic Setup Instructions

    Operator Manual ilex Basic Setup Instructions Electronics Installation All electronic devices are to be installed according to their perspective manufacturer’s user manuals. When installing electronic accessories or placing other items on the top shelf, keep these items at least 2 inches (50mm) away from the vertical edge below the speakers (as shown above to allow room for the monitor when it is in the lowest position and to ensure easy access to controls.
  • Page 10: Moving And Positioning

    Operator Manual ilex Moving and Positioning Center Lock Pedal Pedal Positions Steer Float Lock Caster Modes: Total Lock: Step down on the right end of the caster brake pedal with the red dot to lock both the swivel and roll. Put the casters in this mode during use to prevent any horizontal movement of the unit.
  • Page 11: Instructions For Operation

    31" Operator Manual ilex 790mm 55in Instructions for Operation 140cm ACROSS System Components Ilex55 HANDLES 92in 72in 233cm 182cm 16in Touch Screen Controller 40cm 19in x 28in Blue Tooth Speaker Pairing [48cm x 71cm] Up/Down Emergency Stop 22cm 20in x 20in Master [50cm x 50cm] On/Off...
  • Page 12 Operator Manual ilex Features Maximum Number of Clinical Images Displayed Up to 4 Video Inputs – Total of 5 4 DVI (possible) 1 SDI (possible) 2 SOG (possible) 2 VGA (possible) 1 S Video (possible) 1 Direct PIP DVI (possible) Video Output to monitor 1 HDMI 2.0 Max Resolution...
  • Page 13: Navigating Video Output Menus On Tablet

    Operator Manual ilex On/off Button, use the green toggle switch/thermal breaker to turn the system on and off and to reset the breaker. Up/Down switch, use the monitor elevation toggle switch to adjust monitor height. Maximum duty cycle of the actuator is 10% or 2 minutes of continuous use followed by 18 min.
  • Page 14 Operator Manual ilex Note: In the event the screen is blank preform a system check to see that all devices are powered up. The MSV2 4K will show LED lights on the front panel of the box itself. The monitor will bootup with a visual indicator on screen, as well as the buttons in lower right will light up.
  • Page 15 Operator Manual ilex Ilex55 Typical Layouts Layouts can be customized in the Administration section of the Operating Guide. The Most common layouts have been programed onto your system. The Clinical image can be directed to a location by illuminating the image and dropping it into the layout location (some optimization maybe required).
  • Page 16: Batteries

    Operator Manual ilex Batteries The ilex55 is designed to be used when powered with a hospital grade AC outlet. Battery backup to elevate the monitor is available for emergency or transportation only. When AC power is applied, the actuator backup battery will begin charging until the battery reaches full capacity at which time, the charging will taper off.
  • Page 17: General Cleaning

    Operator Manual ilex 8. General Cleaning Tools: Soft cloth and approved cleaner: o Sodium hypochlorite (generic household bleach) in a solution of 5.25% sodium hypochlorite diluted between 1:10 and 1:100 with water. o Alcohol (generic). o Envirocide. ™ Notes: • For the cleaning of monitor or shelf equipment, please consult corresponding literature for these devices.
  • Page 18 Operator Manual ilex • Front Filter • Proceed as follows: o 1. Remove dust with a dry, lint-free, non-abrasive soft cotton cloth. o 2. Remove fingerprints or grease using a lint-free, non-abrasive soft cotton cloth that is lightly moistened with plain water or a mild commercial glass cleaning product suited for coated glass surfaces.
  • Page 19: Large Monitor Cleaning Barco Only

    Operator Manual ilex • Incidin Foam (Ecolab) • Microzid • Mild detergent • Isopropyl alcohol with concentration < 5% • Household bleach (generic sodium hypochlorite, solutions of 5.25% sodium hypochlorite diluted with water between 1:10 and 1:100) • Precise Hospital Foam Cleaner Disinfect Large Monitor Cleaning Barco Only Cleaning Instructions •...
  • Page 20: Service & Repair

    Operator Manual ilex • Like Cleansafe® optical cleaning liquid Do not use following products: • Alcohol/solvents at higher concentration > 70% • Strong alkalis lye, strong solvents • Acid • Detergents with fluoride • Detergents with ammonia at higher concentration > 1.6% •...
  • Page 21 Operator Manual ilex monitor mounting hardware for loose fasteners. L280-0975 REV A www.imagediagnostics.com Page 18...
  • Page 22: Disposal Of Components

    Operator Manual ilex 11. Disposal of Components The ilex is constructed mostly of steel and aluminum which are easily recycled. Some components can be disassembled before recycling. COMPONENT ITEM RECYCLING GROUP Spindle and Motor Metal (Steel and Copper) Housing Plastic Actuator Cable Copper...
  • Page 23: Specifications

    Operator Manual ilex 12. Specifications Mode of Operation ▪ For continuous use Type of Equipment: ▪ Class I (as defined by IEC 60601-1, 3 Edition ▪ CENELEC EN 60601-1 ▪ ANSI/AAMI ES60601-1 ▪ IEC60601-1 3 Edition Electrical: ▪ Supply Voltage: ▪...
  • Page 24 Operator Manual ilex Product features included with ilex55: ▪ Thermal protector AC input module ▪ Medical grade outlet strip for Monitor & Ancillary power. ▪ Individual cables for monitor power and video input. ▪ 12.5” medical touch screen interface ▪ Detachable 20 foot (6m) AC power cord. ▪...
  • Page 25: Me Equipment And Systems

    Operator Manual ilex 13. ME Equipment and Systems Table 1 per 5.2.2.1.c of IEC 60601-1-2: 2007 for CISPR 11 ME Equipment and ME Systems. Guidance and manufacturer’s declaration –electromagnetic emissions The ILEX55 is intended for use in the electromagnetic environment specified below. The customer or the user of the ILEX55 should assure that it is used in such an environment.
  • Page 26 Operator Manual ilex NOTE U is the a.c. mains voltage prior to application of the test level. Table 4 per 5.2.2.2 of IEC 60601-1-2: 2007. Guidance and manufacturer’s declaration –electromagnetic immunity The ILEX55 is intended for use in the electromagnetic environment specified below. The customer or the user of the ILEX55 should assure that it is used in such an environment.
  • Page 27 Operator Manual ilex Recommended separation distances between portable and mobile RF communications equipment and the ILEX55 The ILEX55 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ILEX55 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the ILEX55 as recommended below, according to the maximum output power of the communications equipment.
  • Page 28: Warranty

    Operator Manual ilex 14. Warranty Warranty details for IDI Products can be obtained directly from Image Diagnostics, Inc. Image Diagnostics, Inc. 310 Authority Drive Fitchburg, MA 01420 USA Or call IDI at (978) 829-0009 or Toll Free (877) 304-5434. The fax number for IDI is (978) 829-0027.

Table of Contents