LTPH-UM-1049-02, Issue 2
T
IMING
The low loop wander (0.3 UI max) of an H2TU-C, when used with compatible regenerators and remote units,
allows the circuit to be used in all critical timing applications, including those that are used to transport Stratum 1

timing.

G
F
ROUND
AULT
The H2TU-C has a Ground Fault Detect (GFD) circuit which detects a ground or a resistive path to ground on any
wire of the HDSL2 loop. This makes the product compliant with the Class A2 requirements of GR-1089.
H2TU-C-319 List 4E
D
ETECT
January 9, 2002
Appendix B - Functional Operation
73