LTPH-UM-1049-02, Issue 2
A
PPENDIX
Power
HDSL2 Span Voltage
CO Supply
Electrical Protection
Fusing
Environmental
Operating Temperature
Operating Humidity
Physical
Height
Width
Depth
Weight
Mounting
HDSL2
Line Code
Transmission
Media
Output
Line Impedance
Maximum Provisioning Loss
Start-up Time
DSX-1
DSX-1 Line Impedance
DSX-1 Pulse Output
DSX-1 Input Level
System
One-way DS1 Delay
Wander (Looped)
Wideband Jitter (Looped)
Narrowband Jitter (Looped)
H2TU-C-319 List 4E
A - S
PECIFICATIONS
0 or -180 ±5 Vdc
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc)
See
"Power Consumption"
Current Drain" on page
Secondary surge and power cross protection on HDSL2 ports. Requires external
primary protection.
Internal; connected to "FUSE ALARM" output on pin 10
-40°F to +149°F (-40°C to +65°C)
5% to 95% (non-condensing)
4.750 in. (12.10 cm)
0.625 in. (1.59 cm)
10 in. (25.4 cm)
0.5 lb (.23 kg)
3192 mechanics shelf
1.552 Mbps OPTIS
Full duplex
One non-loaded, copper, two-wire cable pair
+13.8 dBm ±0.5 dB at 135 (0-450 kHz) at CO side;
+13.5 dBm ±0.5 dB at 135 (0-350 kHz) at remote side
135
35 dB at 196 kHz
30 sec. typical, 1 min. maximum per span
100
pk-pk
6 V
pre-equalized for 0-655 feet of ABAM cable
+1.5 to -7.5 dB DSX
<400 µs per span without regenerators
Meets MTIE T1.101 requirements
0.2 UI maximum
0.1 UI maximum
January 9, 2002
and
"Maximum Power Dissipation"
66.
Appendix A - Specifications
and
"Maximum
65
Need help?
Do you have a question about the HiGain H2TU-C-319 List 4E and is the answer not in the manual?