System Alarm Output Pin - ADC HiGain H2TU-C-319 List 4E User Manual

Adc higain h2tu-c-319 list 4e line unit user manual
Hide thumbs Also See for HiGain H2TU-C-319 List 4E:
Table of Contents

Advertisement

Appendix A - Specifications

System Alarm Output Pin

Pin H on the card-edge connector, shown in
notes apply to pin H:
Pin H replaces the Local Loss of Signal (LLOS) on normal high-density (3192) repeaters.
The normally floating output of pin H can connect to pin 1 of the 1184 or 3192-9F Alarm Card in position 29
of the high density (HD) shelf.
The H2TU-C forces pin H to +5Vdc (maximum of 10 mA) for a system alarm condition. Pin H then remains
at +5 Vdc for the duration of the alarm condition.
If the Wescom 1184 Alarm Card is installed in the shelf, its LOS LED lights for every MNRALM.
The H2TU-C Status LED flashes red for the duration of a system alarm condition.
Setting the ALM option to DIS only prevents the system alarm bus on pin H from being activated for a system
alarm event. The Status LED still flashes red and the ALRM message still displays.
"System Alarms" on page 52
Pin H must never be taken above +5 Vdc or below -60 Vdc.
70
Figure
33, is the H2TU-C System Alarm output pin. The following
describes the system alarms that activate pin H.
January 9, 2002
LTPH-UM-1049-02, Issue 2
H2TU-C-319 List 4E