LTPH-UM-1049-02, Issue 2
Monitor
Performance
------------------------------------------------------------------------------
Time
CV
*22:15
*22:30
*22:45
*23:00
23:15
23:30
23:45
00:00
00:15
00:30
00:45
01:00
-----------------------------------------------------------------------------
Use <Space> to cycle through
choices and <Enter> to view
ID: xxxx--xxxx--xxxx--xxxx 08/01/2001 07:05:33
Table 16. Error Acronyms Used on the HDSL2 Performance History Screens
Error Acronym
ES
SES
UAS
CV
LOSWS
H2TU-C-319 List 4E
Event Log
Config
H2TU-C HDSL2 25 Hour History (Page 1 of 9)
ES
SES
UAS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Press: (N)ext Page, (P)revious Page, C(l)ear History
Interface
Statistics :
Figure 21. H2TU-C HDSL2 25-Hour Performance History
Description
Errored Seconds
Seconds with HDSL2 CRC 1 or LOSW 1
Severely Errored Seconds
Seconds with HDSL2 CRC 50 or LOSW 1
Unavailable Seconds
Based on 10 contiguous SES occurrences
Code Violation
Total count of HDSL2 CRC errors.
Loss of Sync Word Second
Seconds with LOSW
January 9, 2002
Monitoring System Activity and Performance
Inventory
Report
Rlogon
LOSWS
-
-
-
-
-
-
-
-
-
-
-
-
:
H2TU-C HDSL2
25 Hour History
H2TU-C
1
Help
System: OK