H2Tu-R Ds1 Alarm History Screen; Ds1 Alarm Descriptions - ADC HiGain H2TU-C-319 List 4E User Manual

Adc higain h2tu-c-319 list 4e line unit user manual
Hide thumbs Also See for HiGain H2TU-C-319 List 4E:
Table of Contents

Advertisement

LTPH-UM-1049-02, Issue 2
Monitor
Performance
-----------------------------------------------------------------------------
Alarm
RLOS
RAIS
RAI
TX RAI-CI
PRM-NE
PRM-FE
DBER
------------------------------------------------------------------------------
Use <Space> to cycle through
choices and <Enter> to view
ID: xxxx--xxxx--xxxx--xxxx
Screen Alarm Front-Panel Alarm Description
H2TU-C DSI Alarms (see
Figure 25 on page
SPTE
Split Equipment
SPTF
Split Facilities
(a)
LLOS
LLOS
LAIS
LAIS
DBER
xxx-DBER
H2TU-R DS1 Alarms (see
Figure 26
(a)
RLOS
RLOS
RAIS
RAIS
RAI
RRAI
TX RAI-CI
TRCI
PRM-NE
PRMN
PRM-FE
PRMF
H2TU-C-319 List 4E
Event Log
Config
H2TU-R DS-1 Alarm History
First
08/16/01 00:37
08/16/01 00:45
Press: C(l)ear Alarm History
Interface
Statistics :
08/01/2001 07:05:33
Figure 26. H2TU-R DS1 Alarm History Screen
Table 17. DS1 Alarm Descriptions
44)
A test mode initiated by the HMU which splits the AUX port's DSX-1 payload and sends it to the
MUX port.
A test mode initiated by the HMU which splits the AUX facility DS payload from the AUX port
#1 and sends it to the MUX port.
Local Loss of Signal—Loss of the H2TU-C DSX-1 input signal.
Line Alarm Indication Signal—Indicates an AIS (all ones) pattern is being detected at the
H2TU-C DS1 input port. The ALMP option determines whether AIS (default) or LOS is sent
towards the CPE.
Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of
-6
approximately 10
. (xxx denotes either TUC or TUR.)
above)
Remote Loss of Signal— Loss of the H2TU-R DS1 input signal.
Remote Alarm Indication Signal—AIS is being detected at the H2TU-R DS1 input port. By
default (see
Figure 30 on page
Remote Alarm Indication—Indicates an RAI alarm (yellow) from the CPE with errors from the
line unit or network.
Transmit RAI-CI - Remote Alarm Indication at the H2TU-R—Upon reception of an RAI (yellow
LED) from the CPE, the H2TU-R sends an RAI-CI towards the network if the network signal
received at the H2TU-R is clear. If the network signal is impaired (LOS, AIS or LOF), then the
RAI is passed on to the network unaltered. This is applicable to SF or ESF framing. In an all SF
environment, RACI must be enabled to convert SF-RAI to SF-RAI-CI.
Performance Report Monitoring - Near End—The count of the PRM-NE register at the H2TU-R
-6
exceeds the 10
BER threshold at 648 events since 12:00:00 AM.
Performance Report Monitoring - Far End—The count of the PRM-FE register at the H2TU-R
-6
exceeds the 10
BER threshold at 648 events since 12:00:00 AM.
January 9, 2002
Inventory
Report
Last
Status
OK
OK
OK
OK
OK
OK
OK
:
H2TU-R DS-1
Alarm History
H2TU-C
(b)
54) AIS-CI
is sent toward the network.
Monitoring System Activity and Performance
Rlogon
Help
Count
0
0
0
0
0
0
7
System: Alarm
Continued
45

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HiGain H2TU-C-319 List 4E and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

H2tu-c-l4e

Table of Contents

Save PDF