Connecting I/O Connectors
(Soldered Connectors)
1, 2, 3...
Assembling Soldered
Connectors
1, 2, 3...
Use the following procedure when connecting a soldered connector.
1. Align the connector and insert it into the Unit.
2. Use a Phillips screwdriver to tighten the connector's fastening screws.
Phillips screwdriver
Use the following procedure when wiring and assembling a soldered connector
(OMRON C500-CE241).
1. Slide heat-shrink tubing over the power supply wires and solder the wires to
the appropriate pins on the socket.
2. After soldering all of the pins, slide the heat-shrink tubing over the soldered
power supply pins and shrink the tubing by heating it with a heat gun.
Heat-shrink tubing
Power supply wires
Connector
Heat-shrink tubing
Section