Upon completion of a timing event the elapsed time will be displayed in milliseconds on
the LCD display.
EasyLog
► Timing
Switch off
System
If recording Time at A or Stopwatch A to A connect a digital sensor to Input 1:A.
If recording Time from A to B connect a pair of digital sensors to Input 1:A and 2:B.
If the display is turned off, press any button to wake up
EASYSENSE Q. Use the blue buttons (▲▼) to scroll
the menu until the pointer is pointing at Timing.
Press the green button ►to select.
Use the blue buttons (▲▼) to scroll the pointer until it is
pointing at either Stopwatch A to A, Time at A or Time
from A to B. Press the green button ►to select.
EASYSENSE Q will be ready to start taking measurements. When a signal change
from the digital sensor/sensors is received, the timing measurement will be displayed
in seconds (s) on the LCD screen. EASYSENSE Q will then be ready to take the next
measurement.
Example:
What you are measuring
The measurement
The second line shows the current reading, the # number indicates the number of the
reading. The blue (▲▼) buttons can be used to scroll back and forward through the
readings already taken, the # number will indicate the reading number of the
measurement shown. The bottom line shows the average measurement and number
of readings used to calculate this average.
Press the red
button to finish or cancel any pending timing event. Press the green
button ►to return to the main menu.
The data recorded will be stored as a data set, which can be downloaded
to the computer for display and analysis using Retrieve remote from
the Home page in the EASYSENSE
The collected data is a time measurement. For the software to be able to perform
calculations e.g. speed, velocity or acceleration, it is necessary to enter the parameters
© Data Harvest Group Ltd.
Stopwatch A to A
► Time at A
Time from A to B
Time at A
= 0.00000 s
t = 0.000000s
The average measurement
software.
14
Time at A
= 0.00000 s
t=0.000000 s
Easy Log
► Timing
Switch off
System
Stopwatch A to A
► Time at A
Time from A to B
The reading number of this measurement
#0
n=0
over this number of readings
DO185 (2)
#0
n=0