B2 Operating Modes - Eldat Easywave RCR02E5002A01 Manual

Din rail receiver
Table of Contents

Advertisement

B
Operation
B2
Operating Modes
Press the P button to specify whether you want to
programme a transmitter in 2-button operation or
in 1-button operation.
Then press the M button repeatedly to select the
desired operating mode. The operating mode cur-
rently selected is shown in the digital display.
Once you have selected the output to be program-
med, the desired transmission code can be pro-
grammed with the selected combination of opera-
tion and operating modes.
To do this, simply press the button for the transmit-
ter that you wish to programme.
Operating Mode
ON and OFF switches with 1- or 2-button operation.
ON/OFF
If the transmitter button is pressed for longer than 1.6 s when using 1TB,
I/O
all outputs paired with the transmitter will be switched off.
When a transmitter button is pressed, the relay is activated for the duration of time specified in the operating mode.
PULSE
Only possible with 1TB, with 2TB both buttons trigger the same operation.
0.5 s
Output is activated for 0.5 seconds
1 s
Output is activated for 1.0 seconds
2 s
Output is activated for 2.0 seconds
The length of the switching time is permanently programmed. The relay switches ON for the duration of the selected time.
TIMER I
The switching time can be retriggered (retrig), i.e. each new keystroke, before the time has expired, starts the switching time again.
3 min
Switch-off after 3 minutes without shutdown warning.
7 min !
Switch-off after 7 minutes without shutdown warning
15 min !
Switch-off after 15 minutes without shutdown warning
The length of the switching time can be set by the operator. The user must set a time between 1 and 60 s, which is then multiplied
by the multiplier of the selected operating mode to result in the switching time. The factory settings are programmed to 30 seconds x
TIMER II
respective multiplier (1, 10, 100, 1,000). The maximum time is calculated using the maximum timeout of 60 seconds (when changing
the switching time) and the multiplier for the operating mode. Retriggering the switching time is also possible with this timer.
Multiplier 100
s x 100 !
Shutdown warning
Multiplier 1
s x 1
No shutdown warning
Multiplier 10
s x 10
No shutdown warning
Multiplier 100
s x 100
No shutdown warning
Multiplier 1.000
s x 1.000
No shutdown warning
DEAD MAN
The output is active for as long as the transmitter button is held down.
max. 36 s
Switches OFF when the button is released or automatically after 36 seconds.
Only possible with 2TB! All programmed transmission codes are combined according to an AND / OR logic. This operating mode is
subordinate to all other operating modes! Therefore, this operating mode does not function when a command is sent from a paired
LOGIC
transmitter. ALL other operating modes must be OFF! If a different operating mode switches ON, LOGIC cannot switch OFF. Switching
a different operating mode OFF while LOGIC is ON resets the LOGIC function. (However, it can be started again at any time.)
OR relationship: if one of the programmed transmitters sends an A telegram (ON),
the relay switches on.
Logic
/
AND relationship: if all of the programmed transmitters, that previously sent an A,
sent a B telegram (OFF), the relay switches off.
*)
The shutdown procedure (!) is indicated as follows: 30 seconds before the end: output switches OFF 1x briefly and then back ON. 15 seconds before the end: output switches OFF 2x briefly then back ON.
When using energy-saving lamps, a shutdown warning is not possible
and using this function can result in damage to the lamp.
In 2-button operation (2TB), switching ON trans-
mitter buttons A or C starts or retriggers the TI-
MER functions. Transmitter buttons B or D switch
OFF or stop the TIMER function. Only one trans-
mission button must be programmed in the recei-
ver, the code for the second button is assigned
automatically.
If a PULSE or DEAD MAN function is program-
med in 2TB, both buttons always perform the
same function!
Switching time: min. 100 s, max. 1.66 h
30 seconds before the time expires.
*)
Switching time: min. 1 s, max. 60 s
Switching time: min. 10 s, max. 10 min
Switching time: min. 100 s, max. 1.66 h
Switching time: min. 16.66 min, max. 16.66 h
*)
*)
In 1-button operation (1TB), each button switches
ON and OFF alternately or triggers a PULSE.
Each button can start and retrigger the TIMER
and actuate the DEAD MAN'S CONTROL.
Each button must be individually programmed in
the receiver, there is no automatic assignment.
The LOGIC function cannot be used with 1TB.
Therefore, the set-up is ignored in this operating
mode.
2-Button operation (2TB)
1-Button operation (1TB)
transmitter button
transmitter button
A
B
C
D
A
ON
OFF
ON
OFF
ON/
OFF
ON
ON
ON
OFF after Timeout
ON
ON
ON
OFF after Timeout
ON
ON
ON
OFF after Timeout
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
EIN/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON/
OFF
ON/
OFF
ON/
retrig
retrig
retrig
ON
ON
ON
B
C
D
ON/
ON/
ON/
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON/
ON/
ON/
retrig
retrig
retrig
ON
ON
ON
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easywave rcr02e5004a01Easywave rcr02 series

Table of Contents