Wiring method
①
Proceed carefully, as incorrect wiring can cause damage.
②
Use a DC power supply with sufficient capacity and a low ripple.
③
Turn off the power supply to remove and insert the connector.
WIRE COLOR
PINK-BLACK2
GREEN-BLACK2
BLUE
BLUE-BLACK2
GRAY-BLACK1
ORANGE-BLACK1
GREEN-BLACK1
PINK-BLACK1
BLUE-BLACK1
GRAY
ORANGE
GREEN
PINK
NOTE: WIRE COLOR WHEN OPTION CABLE CONNECTOR IS USED.
Setting method
Ex) In case that setting pressure is 0.3MPa on ITV2030(0.5MPa specification).
(0.3MPa/0.5MPa) × 1023 = 614 (Decimal)
Binary data of "614"( Decimal) is "10 0110 0110".
VALUE
1
SIGNAL
MSB
10bit
INPUT
ON
By inputting 12-24VDC between common and each signal wire, input states becomes
"ON". (Common is no polarity.)
△
!
CABLE FOR SINGNAL
(NOTE)
POWER SUPPLY (DC24V)
POWER SUPPLY (DC0V)
SIGNAL COMMON (NO POLARITY)
MSB
LSB
0
0
1
9bit
8bit
7bit
OFF
OFF
ON
Caution
SINGNAL NAME
10bit
9bit
8bit
7bit
6bit
5bit
4bit
3bit
2bit
1bit
1
0
0
6bit
5bit
4bit
ON
OFF
OFF
- 5 -
1
1
0
LSB
3bit
2bit
1bit
ON
ON
OFF