Waste Water - EauVation Acqua 80 Service Instructions Manual

Table of Contents

Advertisement

Setup and connection
Installation diagram
 Install the pressure reducer (3) and water clock (5) easily accessible to a wall or in kitchen cabinet. Do not
yet plug in any hoses between the components.
Item
Description
1
Water supply (max. 35 °C)
Reduction 3/4" or 3/8"
2
3
Pressure reducer
4
Pressure gauge with T-piece (installed temporarily)
5
Water clock
6
Acqua 80
IMPORTANT: Do not insert the hygiene filter yet.
 Wash hands, put on protective gloves and spray with EAUVATION N° 2.
 Connect hoses to all the components. Before inserting the hoses, spray the end of the hoses with
EAUVATION N° 2. Do the same for the hose connections of the components.
The pressure gauge is removed again later. Therefore, the hose between the pressure gauge and the
water clock must be sufficiently long.
 All connectors must be secured with locking clips.
Setting the water clock
 Set 8000 l water volume (12).

4.3 Waste water

The drip tray can be connected to the waste water.
Waste water connection requirements:
 Trap
 Level lower than the drip tray
 Hose to the waste water connection has a steady gradient to ensure no backlog of water
6
 Insert the water connection hose into the
"FILL THE ICE-BANK" connection.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents