15 Safety inspection
The following safety checks must be performed on the water dispenser every 2 years.
15.1 Check relief valve
Possible discharge of carbonic acid
Splashes cause cold burns.
Wear protective gloves and protective goggles.
Warning
Gas pressure reducer
Close the shut-off valve after the gas pressure reducer.
Fully open the valve on the carbonic acid bottle.
Turn the set screw (3) in clockwise direction until the safety valve opens. This should happen at approx.
5.5 bar.
Reset the previous operating pressure.
Open the shut-off valve after the gas pressure reducer.
15.2 Check for leaks
Fully connect the valve to the carbonic acid bottle.
Watch the pressure gauge of the high pressure side for 3 - 5 minutes. In this period, the pressure may not
drop.
In necessary, locate leaks with leak detection spray.
Item
Description
1
High pressure side (carbonic acid bottle)
2
Manometer (operating pressure = pressure
after the pressure reducer)
3
Adjusting screw
Clockwise rotation increases the pressure
4
Manometer
(pressure in the carbonic acid bottle)
5
Low-pressure side (connection for the car-
bon dioxide hose)
Safety inspection