Hygiene maintenance
Replacing the hygiene filter with dummy plug (not for first commissioning)
Installing the maintenance cartridge
For the hygiene maintenance, the entire system is flooded with the maintenance cleaner EAUVATION N° 1.
For a thorough cleaning, it is important that the cleaning agent enters the cycle as early as possible. There-
fore, the maintenance cartridge must be installed directly after the water stop cock.
before
after
 Insert the cartridge head (3) between the water stop cock (1) and the pressure reducer (2).
 Before inserting the hoses, spray the end of the hoses with EAUVATION N° 2. Also spray the hose con-
nections at the cartridge head (3).
 Fill 300 ml of maintenance cleaner EAUVATION N° 1 into the maintenance cartridge (4).
12
 Remove the bracket (1) with hygiene filter (2).
 Remove the hygiene filter (2).
 Spray the inside of the filter head (3) with EAUVATION N° 2.
 Spray the dummy plug (4) with EAUVATION N° 2 and screw
into the filter head (3).
 Close the lever at the filter head (turn to the right).
 Install the bracket (1).
 Screw the upper panel tight.
 Plug in the mains plug.