EauVation Acqua 80 Service Instructions Manual page 15

Table of Contents

Advertisement

Let the maintenance cleaner act
 Turn on the water dispenser.
 Open the water stop cock.
 Draw still water until a pressure shock occurs.
 Dispose of water.
 Draw approx. 100 ml of still water. When drawing the water, hold a chlorine test strip into the water. As
soon as the colour changes from white to purple, the maintenance cleaning agent has come through.
 Dispose of water.
 Draw carbonated water. When drawing the water, hold a chlorine test strip into the water. As soon as the
colour changes from white to purple, the maintenance cleaning agent has come through.
 Dispose of water.
 Let the cleaning agent act for approx. 5 minutes. Draw approx. 50 ml of each water type in between.
Rinse the maintenance cleaning agent
 Draw approx. 10 l of each water type and dispose of it. When drawing, alternate between the two water
types.
 Draw approx. 200 ml of each water type.
 Using the chlorine test strip, check whether the water still contains maintenance cleaner (colour changes
white -> purple).
 Dispose of water.
 Keep drawing water from both water types until the colour no longer changes.
 Close the water stop cock.
 Depressurise the water pipe by pressing the button for still water.
 Turn off the water dispenser.
 Pull the mains plug.
Removing the maintenance cartridge
before
after
 Removing the maintenance cartridge (3+4).
 Spray the hose end (1) with EAUVATION N° 2. Also spray the hose connection at the pressure reducer (2).
 Plug the hose (1) into the pressure reducer (2).
IMPORTANT
Check the end of the hose. If there are any scores on the hose, shorten the hose or re-
place it to ensure a tight plug connection.
Hygiene maintenance
13

Hide quick links:

Advertisement

Table of Contents
loading