Setup and connection
Open the valve of the carbonic acid bottle and check whether carbonic acid leaks as gas (not in liquid
form).
Close the valve of the carbonic acid bottle.
Screw the gas pressure reducer tightly to the valve of the carbonic acid bottle using a suitable open-end
spanner.
Connect a shut-off valve to the gas pressure reducer with a short hose (approx. 100 mm).
Close the shut-off valve.
Connect the water dispenser and the water shut-off valve with a hose.
All connectors must be secured with locking clips.
Do not yet open the valve of the carbonic acid bottle.
Point out to the operator that he/she is responsible for the following:
The room in which the water dispenser and the carbonic acid bottle are placed must be sufficiently
large ( 4.1). If the room is too small: ensure adequate ventilation or have a gas detector installed.
Access to this room must be marked with the warning signs W18 with additional text and W029.
Create a safety risk assessment.
Place a sign where the carbonic acid bottle is placed about the maximum size of the bottle.
Keep a logbook.
Additional text
W18
4.5 Electrical connection
Connection only to alternating current via correctly installed earthed socket.
Maximum fuse protection: 16 A
Installation must be in accordance with the rating plate.
Danger
Install a residual current circuit breaker with a release current of 30 mA in the electrical
feeder.
The device must remain switched on permanently.
Caution
Plug the mains cable into the device and the on-site socket.
8
W029