Hygiene maintenance
Installing the hygiene filter
 Set the flow meter ( 7.1).
 Screw the upper cover tight.
 Plug in the mains plug.
 Turn on the water dispenser.
 Open the water stop cock.
 Draw approx. 2 litres of still water and dispose of it.
 Draw approx. 2 litres of carbonated water and dispose of it.
 This will wet the hygiene filter.
Finalisation
 Spray protective gloves with EAUVATION N° 2.
 Draw a sterile water sample. Label water sample and refrigerate. Water sample must reach laboratory
within 24 hours.
Note: Only draw water sample if agreed upon with customer.
 Clean the drip tray.
 Clean the outside of the water dispenser with EAUVATION N° 3.
IMPORTANT
Do not wipe the water outlet as this may cause germ contamination.
14
 Turn off the water dispenser.
 Pull out the mains plug.
 Unscrew the upper cover plate and remove it.
 Remove the bracket (1) with hygiene filter (2).
 Remove the dummy plug (2).
 Spray the inside of the filter head (3) with EAUVATION N° 2.
 Insert a new sterile hygiene filter (1) into the filter head (2).
Before inserting the filter, spray the plug connection of the
hygiene filter with EAUVATION N° 2.
IMPORTANT
Do not touch the plug connection of the hy-
giene filter (hygiene).
 Close the lever at the filter head (turn to the right).
 Install the bracket (1).