Hygiene maintenance
Installing the hygiene filter
Set the flow meter ( 7.1).
Screw the upper cover tight.
Plug in the mains plug.
Turn on the water dispenser.
Open the water stop cock.
Draw approx. 2 litres of still water and dispose of it.
Draw approx. 2 litres of carbonated water and dispose of it.
This will wet the hygiene filter.
Finalisation
Spray protective gloves with EAUVATION N° 2.
Draw a sterile water sample. Label water sample and refrigerate. Water sample must reach laboratory
within 24 hours.
Note: Only draw water sample if agreed upon with customer.
Clean the drip tray.
Clean the outside of the water dispenser with EAUVATION N° 3.
IMPORTANT
Do not wipe the water outlet as this may cause germ contamination.
14
Turn off the water dispenser.
Pull out the mains plug.
Unscrew the upper cover plate and remove it.
Remove the bracket (1) with hygiene filter (2).
Remove the dummy plug (2).
Spray the inside of the filter head (3) with EAUVATION N° 2.
Insert a new sterile hygiene filter (1) into the filter head (2).
Before inserting the filter, spray the plug connection of the
hygiene filter with EAUVATION N° 2.
IMPORTANT
Do not touch the plug connection of the hy-
giene filter (hygiene).
Close the lever at the filter head (turn to the right).
Install the bracket (1).