About this manual Service Instructions Acqua 80 Water Dispenser Contents About this manual ------------------------------------------------------------------------------------------------------- 2 Safety notes ---------------------------------------------------------------------------------------------------------------- 2 General safety notes ------------------------------------------------------------------------------------------------------ 2 Carbonic acid bottle ------------------------------------------------------------------------------------------------------- 2 Maintenance and repair work ------------------------------------------------------------------------------------------- 3 Device overview / main components ------------------------------------------------------------------------------ 3...
About this manual About this manual This manual is intended exclusively for the use by service technicians authorised by EauVation. The following symbols are used in these instructions: Symbol Meaning Warning of potentially serious or fatal injuries to persons if the described precautionary measures are not taken.
The plug must be pulled from the power supply for all installation and maintenance work. Maintenance and repair work may only be performed by service technicians authorised by EauVation. Inappropriate maintenance or repair work can result in serious risks for the user, for which EauVation shall not accept liability.
Page 6
Button for advanced hygiene maintenance (not implemented yet) Solenoid valve for still and carbonated water Carbonator tank Hygiene maintenance cleaner Hygiene spray Acid spray cleaner Cleaning tablets for water EAUVATION N° 1 EAUVATION N° 2 EAUVATION N° 3 bottles and carafes EAUVATION N° 4...
Use the hose cutter to ensure the hose cross section remains round and that the hose is cut straight. Caution Required materials Reduction 3/4” or 3/8” Pressure reducer Water clock Water hose Pressure gauge Dummy plug Locking clip Hygiene spray Hose cutter EAUVATION N° 2...
Acqua 80 IMPORTANT: Do not insert the hygiene filter yet. Wash hands, put on protective gloves and spray with EAUVATION N° 2. Connect hoses to all the components. Before inserting the hoses, spray the end of the hoses with EAUVATION N°...
Item Description Carbonic acid bottle Gas pressure reducer Shut-off valve Acqua 80 Place the carbonic acid bottles in an upright position. Secure the carbonic acid bottles to prevent them from falling over by using the supplied securing strap.
Setup and connection Open the valve of the carbonic acid bottle and check whether carbonic acid leaks as gas (not in liquid form). Close the valve of the carbonic acid bottle. Screw the gas pressure reducer tightly to the valve of the carbonic acid bottle using a suitable open-end spanner.
Unscrew the upper cover plate and remove it. Remove the bracket (1). Spray the inside of the filter head (3) with EAUVATION N° 2. Spray the dummy plug (4) with EAUVATION N° 2 and screw into the filter head (3).
Draw approx. 1000 ml of still water and dispose of it. Read the pressure gauge: the flow pressure should be at least 1.5 bar. Remove the pressure gauge. Before plugging in, spray the hose end with EAUVATION N° 2.
Dispose of drawn water when it is no longer required for the measurement. Observe the following during hygiene maintenance: Clean working clothes Wash your hands Keep spraying hands / protective gloves with EAUVATION N° 2 Required materials Protective gloves Protective goggles EAUVATION N°...
Page 14
Insert the cartridge head (3) between the water stop cock (1) and the pressure reducer (2). Before inserting the hoses, spray the end of the hoses with EAUVATION N° 2. Also spray the hose con- nections at the cartridge head (3).
Page 15
Removing the maintenance cartridge (3+4). Spray the hose end (1) with EAUVATION N° 2. Also spray the hose connection at the pressure reducer (2). Plug the hose (1) into the pressure reducer (2). IMPORTANT Check the end of the hose. If there are any scores on the hose, shorten the hose or re-...
Page 16
Remove the bracket (1) with hygiene filter (2). Remove the dummy plug (2). Spray the inside of the filter head (3) with EAUVATION N° 2. Insert a new sterile hygiene filter (1) into the filter head (2).
Setting the water dispenser Setting the water dispenser 7.1 Setting the flow regulator for carbonated water The amount of water which is drawn per unit of time is set on the flow regulator (1). Factory setting: 200 ml in 8 seconds (1.5 l/min = 150 ml/6 s) ...
Setting the water dispenser 7.2 Setting the portion sizes Each button can be set to how much water should flow when pressing the button. Factory setting: Button 3 and 4: 0.2 l Button 2 and 5: 0.7 l Setting the programming mode ...
Maintenance work 7.3 Setting the refrigeration (1): Thermostat Clockwise rotation: Temperature is lowered Anti-clockwise rotation: Temperature is increased If larger volumes of cooled water are regularly drawn: Set the thermostat to 6 so that an ice-bank can form. Maintenance work Scope of work Interval...
Make sure the glass pipe is not damaged before installation. Warning 9.2 Descaling the water outlet pipe Dissolve one tablet of EAUVATION N° 4 in 20 ml of water in a small measuring cup. Hold the calcified end of the pipe into the solution.
Insert the water connection hose into the “IN H O” connection. Before inserting the hoses, spray the end of the hose with EAUVATION N° 2. Unscrew the upper cover plate and remove it. Using curved needle-nose pliers, add one tablet to prevent the formation of algae to the water bath.
Water clock 12 Water clock 12.1 Inserting the batteries Open the battery compartment (1). Insert two batteries (type AAA). Pay attention to correct polarity of the batteries. Close the battery compartment (1). 12.2 Setting the capacity Press and hold down button (2). ...
Decommissioning the water dispenser 13 Decommissioning the water dispenser For a period of disuse under 3 weeks, the water dispenser can be decommissioned without the need for preservation. To do this, perform the following steps: Close the water stop cock. ...
Malfunctions 14 Malfunctions Errors Possible cause Remedy Still water Water jet is too weak Water pressure is too low Adjust the water pressure (mini- mum water pressure = 1.5 bar). Water jet is too strong Water pressure is too high Set the pressure reducer (...
Safety inspection 15 Safety inspection The following safety checks must be performed on the water dispenser every 2 years. 15.1 Check relief valve Possible discharge of carbonic acid Splashes cause cold burns. Wear protective gloves and protective goggles. Warning Item Description High pressure side (carbonic acid bottle)
Technical data 16 Technical data Height 510 mm Width 360 mm Depth 562 mm Weight 34 kg Cooling output 80 l / h Dispensing water temperature 5–12 °C Setting the CO pressure Max. 4 bar Sound pressure level during normal operation Max.
Circuit diagram 17 Circuit diagram Component Mains cable On / off switch Terminal block Transformer not available Pump Thermostat Compressor Ventilator pressure switch Carbonator tank Flow meter for still water Flow meter for carbonated water Solenoid valve for still water Solenoid valve for carbonated water UVC lamp...