5.9 Perform hygiene maintenance
( 6)
6
Hygiene maintenance
Danger of chemical burn
Cleaning agents can cause severe chemical burns.
Wear protective clothing, protective gloves and protective goggles.
Warning
Set up a warning sign during hygiene maintenance, warning of the water release.
Do not use drinking glasses / cups for the hygiene maintenance.
Dispose of drawn water when it is no longer required for the measurement.
Observe the following during hygiene maintenance:
Clean working clothes
Wash your hands
Keep spraying hands / protective gloves with EAUVATION N° 2
Required materials
Protective gloves
Protective goggles
EAUVATION N° 1
EAUVATION N° 2
EAUVATION N° 3
EAUVATION N° 4
Sterile hygiene filter
Maintenance cartridge
Dummy plug
Chlorine test strip
Hose cutter
Water hose (approx. 300 mm long)
Flat-blade screwdriver
Phillips head screwdriver
0.2 l and 1.0 l measuring cup
Bucket (10 l)
Preparation
Wash hands.
Put on protective clothing.
Put on protective gloves and spray with EAUVATION N° 2.
Put on protective goggles.
Draw a sterile water sample. Label water sample and refrigerate. Water sample must reach laboratory
within 24 hours.
Note: Only draw water sample if agreed upon with customer.
Check the water clock: How much water has been drawn since the last maintenance?
The hygiene filter has a capacity of 8300 litres or a service life of six months. Hygiene maintenance
should be performed earlier if more than 8300 litres of water have been drawn during the last six months.
Close the water stop cock.
Depressurise the water pipe by pressing the button for still water.
Turn off the water dispenser.
Pull the mains plug.
Unscrew the upper cover plate and remove it.
Set flow regulator to "Maximum" (7.1).
Checking the water outlet pipe
Check whether the water outlet pipe is calcified. If required, descale (9).
Hygiene maintenance
11