Specially for measuring systems type MLO−POT−...−TLF:
Mount the measuring system so that it is electrically
S
isolated.
If the measuring system is to be used in a dusty or
S
dirty environment, mount it so that the actuator slide
faces downwards.
Specially for measuring systems type MLO−POT−...−LWG:
In order to earth the system, connect the earth/ground
S
cable on the flat plug of the measuring system to the
earth connection on the SPC11.
Specially for DNCI−...
In order to earth the earth connection of the SPC11
S
and the earth connection of the drive, connect them
with the same earth potential.
Fixed stops
Use fixed stops to limit the working stroke. With drives
S
of type DGP(I)(L)−..., the working stroke should not
project into the range of the end position cushioning.
Mass load
Fasten the permitted mass load to the slide without
S
play.
Festo SPC11−... 0404a English