CAB 4712 Service Manual page 43

Flag applicator
Hide thumbs Also See for 4712:
Table of Contents

Advertisement

7
Failure
No. Error pattern
5
6
7
Possible error cause
electrostatic charge
Application height not correct
Product too soft and flexible
In the basic position, pads are not aligned parallel to
each other
Value for the parameter Lock time too small.
Troubleshooting
Install an external
ionizing blower.
Readjust the stopper
Clamp the product if
possible.
Fix the product on the
supports
Align the pad precisely
using the setting tool for
pad assembly
Increase the value for
the parameter Lock time
and thus delay the pliers
opening.
Throttle valve (2.03)
Set the throttle valve
on the cylinder 'flag'
(2.03) to the specified
too closed for closing
value according to the test
the pads.
report.
Open further if necessary.
43