2.4.1. POSSIBLE FAILURES AND THEIR ELIMINATION

Warning! : Only technically qualified service centres can perform the operations
described below!
Warning! : Before resetting the safety thermostat, it is always necessary to
eliminate the problem causing its activation!
Problem and possible cause
The content of the vat does not
heat up:
 the safety thermostat has been
activated;
 the heating elements have a
failure;
 selector/switch failure.
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Pentole elettriche E7PI
Access to components and operation
Safety thermostat
Remove the lower, right front panel, unloose the
screws and remove the support of the connector-
block.
The safety thermostat can be reached once the lid
of the connector-block has been removed.
Heating elements
The heating elements can be reached once the
lower front panel has been removed.
Selector/switch
To reach the selector/switch, remove the upper front
panel.
Ignition plug and thermocouple
Remove the lower front panel.