Cleaning Performance
Vacmaster vacuum cleaners are tested for endurance. If your motor is operating, then the most
likely cause for a loss in suction is a blockage or an opening in the vacuum.
To maintain a high cleaning performance from your machine, it is important to replace or clean
cartridge filters as necessary. Replace full dust collection bags to prevent performance drops. A
performance drop with clean filters can only be caused by a blockage in the tools or the hose.
PROBLEM
The appliance does not
work.
Dust is escaping from
the motor cover.
Power tool take-off
socket does not work.
Low suction power and
high operating noise /
vibrations.
The air flow indicator
is still red flashing
after completing filter
cleaning operation.
TROUBLESHOOTING
POSSIBLE CAUSE
No power.
Functional fault in the power cord,
switch, or motor.
The cartridge filter is missing or
damaged.
Misuse the foam filter when dry
vacuuming.
Power tool wattage is not
compatible with the power tool
take-off socket.
Incorrect operating mode selected.
Dust bag or disposable bag is full.
Suction nozzle, hose, or tank inlet
is blocked.
Cartridge filter is blocked.
Float valve has closed.
Power regulator switch is set to
minimum.
Suction nozzle, hose, or tank inlet
is blocked.
The cartridge filter has been
contaminated heavily.
The container is full.
Check the power supply and fuse.
Have the damaged part checked by
qualified personnel or contact the
after sales helpline.
Put in a cartridge filter or replace it.
Replace the foam filter with the
cartridge filter.
Check the wattage is compatible
with the power tool take-off socket.
Ensure the switch is moved into
position II.
Replace the dust bag or disposable
bag.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Remove the cartridge filter and
clean.
Empty the container of any liquid
waste and ensure the float value
located underneath the filter is able
to move freely.
Adjust variable power regulator.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Remove and clean or replace with a
new filter.
Empty the container.