Female connector M12 (8‑pin)
Cable cross section stranded wire
Connection cable
Description
Properties
Connection
Signal name
8
7
6
5
4
3
2
1
Unit
mm
2
RKB0006 (optional accessory; see chapter "Accesso‐
ries" → "RKB0006, Interface Cable")
Fig.6-20:
Function, pin assignment, properties
For reasons of noise immunity, the interface should not be perma‐
nently connected!
The serial interface (RS232) is required for programming, parameterization and
diagnosis during commissioning and servicing (with a PC and the commission‐
ing software Rexroth IndraWorks D).
Electrical isolation
None
Number of nodes
Maximum 1
Transmission distance
Up to 15 m
Transmission rates
9600/19200 baud
The interface does not have a galvanic isolation. The potential dif‐
ference between control section and connected data terminal
equipment must always be less than 1 volt.
Electric Drives
| Bosch Rexroth AG
and Controls
Function
GND
Reference potential
RxD
Receive Data
TxD
Transmit Data
RTS
Request To Send
n. c.
Reserved, not connected
n. c.
Reserved, not connected
Input "release brake":
connect X2.1 to X2.2 to release brake
Min.
Max.
0,25
83/152