80/152
Bosch Rexroth AG | Electric Drives
Connection Points
6.2.10

Control Voltage Supply +24V, 0V

View
Screw connection
M6 thread at device (terminal block)
tightening torque
power consumption
voltage load capacity
polarity reversal protection
Current carrying capacity "looping through" from 24V to 24V, 0V to 0V
(contact bars in scope of supply of accessory HAS01)
with contact bars -072
and Controls
PELV for 24V power supply unit
For the 24V supply of the devices of the Rexroth IndraDrive range,
use a power supply unit or a control-power transformer with pro‐
tection by PELV 1) according to IEC 60204-1 (section 6.4).
In the scope of CSA/UL, the data of the control-power transformer
are limited to:
Max. output voltage: 42.4 V
Max. output power: 10000 VA
Identifica‐
tion
+24V
0V
Unit
Nm
W
V
A
Fig.6-16:
Function, pin assignment, properties
Protective Extra-Low Voltage
1)
Rexroth IndraDrive Mi | Project Planning Manual
peak
Function
power supply
connection to neighboring devices with contact bars from ac‐
cessory HAS01.1
reference potential for power supply
connection to neighboring devices with contact bars from ac‐
cessory HAS01.1
Min.
5,5
P
(see technical data)
N3
U
(see technical data)
N3
within the allowed voltage range by internal protective diode
220
or 30 V
ac
Max.
6,5

Advertisement