Project Planning Manual | Rexroth IndraDrive Mi
Notes on Installation
CAUTION
Adjusting Mounting Depths
Fig.6-14:
Connection of contact bars
If in special cases it is not possible to use the contact bars provided to establish
the connection, the connection must be established using the shortest possible
twisted wires.
Risk of damage by voltage arcing!
Insulate ring terminals and lines with a heat-shrinkable sleeve. Afterwards only
strip the insulation of the contact surface of the ring terminal.
 When connecting the lines, make sure the polarity is correct.
Length of twisted wire
Line cross section
Line protection
Dielectric strength of single
strand against ground
Fig.6-15:
DC bus line
HMV01 and HCS03 devices have greater mounting depths than the electronic
control system KCU. For connecting the electronic control system KCU to an
HMV01 or HCS03 device, you must therefore use the control cabinet adapter
HAS03.1-002 which compensates the different mounting depths (see also
chapter "Accessories").
Electric Drives
| Bosch Rexroth AG
and Controls
Max. 2 m
Min. 10 mm
2
; but not smaller than cross section of
supply feeder
By means of fuses in the mains supply
≥ 750 V (e.g.: strand type – H07)
79/152