Bosch Rexroth IndraDrive Mi Project Planning Manual page 130

Drive systems
Hide thumbs Also See for Rexroth IndraDrive Mi:
Table of Contents

Advertisement

122/152
Bosch Rexroth AG | Electric Drives
Mounting and Installation
and Controls
Drive system Rexroth IndraDrive Mi with HMV01 supply unit:
24V
24V supply
DST
Transformer (optional)
F
Fuses
HMD, HMS
Inverter (optional)
HMV01
Supply unit
HNF
Mains filter
HNL
Mains choke
K1
Mains contactor (only for supply units without integrated mains contac‐
tor, e.g. HMV01.1R-W0120)
KCU
Electronic control system
KSM
Distributed servo drive
MSK
Servo motor (optional)
RHS
Terminal connector
RKG
Encoder cable (optional)
RKH
Hybrid cable
RKL
Motor cable (optional)
X14
Mains synchronization (only with regenerative HMVs)
X3.2
Connection of hybrid cable RKH at first KSM
Fig.9-6:
Drive system Rexroth IndraDrive Mi with HMV01