44/152
Bosch Rexroth AG | Electric Drives
Technical Data of the Components
Duty Cycle
DC Continuous Power PDC
and Controls
P
Load
P
Electric losses
V
Θ
Temperature
Θ
Highest temperature (motor housing)
max
t
Time
T
Cycle duration
C
Δt
Operating time with constant load
P
Δt
Idle time
V
Fig.5-2:
Operating modes according to EN 60034-1: 1998
Operating mode S3 (intermittent duty) is supplemented by specification of the
duty cycle ED %. The duty cycle is calculated as follows:
ED
Relative duty cycle in %
Δt
Operating time with constant load
P
Fig.5-3:
Relative duty cycle
The values specified in the documentation have been determined on the basis
of the following parameters:
Cycle duration: 1 min
Duty cycle ED: 25%
Power consumption at the point of maximum power (PML); mechanical power
and power dissipation