Values displayed
Output power (W) - depending on the device type (MultiString), when the Enter key is
under the NOW
pressed,
menu item
(MPPT1 / MPPT2) are displayed
AC reactive power (VAr)
Grid voltage (V)
Output current (A)
Grid frequency (Hz)
Solar voltage (V) - U PV1 from MPP Tracker 1 and U PV2 from MPP Tracker 2 (MPPT1
/ MPPT2), if MPP Tracker 2 is activated (see "The Basic menu" - "Menu items in the Basic
menu")
Solar power (A) - I PV1 from MPP Tracker 1 and I PV2 from MPP Tracker 2 (MPPT1 /
MPPT2), if MPP Tracker 2 is activated (see "The Basic menu" - "Menu items in the Basic
menu")
Fronius Eco: The total current from both measuring channels is displayed. Both channels
are shown separately in SolarWeb.
Time date - Time and date on the inverter or in the Fronius Solar Net ring
Values displayed
Energy fed in (kWh / MWh)
under the LOG
Energy fed into the grid during the period in question.
menu item
When the Enter key is pressed,
MPP Tracker 2 (MPPT1 / MPPT2) are displayed, if MPP Tracker 2 is activated (see "The
Basic menu" - "Menu items in the Basic menu")
There may be discrepancies compared with values displayed on other measuring instru-
ments because of differences in measuring methods. As far as the billing of the energy
fed in is concerned, the only binding display values are those produced by the calibrated
measuring instrument provided by the utility company.
Max. output power (W)
Largest amount of energy fed into the grid during the period in question.
When the Enter key is pressed,
MPP Tracker 2 (MPPT1 / MPPT2) are displayed, if MPP Tracker 2 is activated (see "The
Basic menu" - "Menu items in the Basic menu")
Yield
Amount of money earned during the period in question
Like the "Energy fed in" figure, the yield figure may also exhibit discrepancies compared
with other measured values.
The subitem "Energy yield" in the "Menu items in the Set-up menu" section explains how
to select a currency and charge rate.
The factory setting depends on the respective country setup.
CO2 savings
CO2 emissions saved during the period in question
The subitem "CO2 factor" in the "Menu items in the Set-up menu" section explains how
to set the CO2 factor.
Maximum grid voltage (V) [phase indicator - neutral or phase - phase]
Highest grid voltage measured during the period in question
When the Enter key is pressed,
26
the individual output powers for MPP Tracker 1 and MPP Tracker 2
the individual output powers for MPP Tracker 1 and
the individual output powers for MPP Tracker 1 and
the individual grid voltages are listed