Kozy-World GFNC2829 Quick Start Manual

Vent-free gas fireplace system

Advertisement

Quick Links

Kozy-World
GFNC2829
GFPC2830

Table of Contents

Safety Information Warnings.................................2
Air for Combustion and Ventilation......................4
Installation................................................................6
Operating heater.....................................................11
Cleaning&Maintenance........................................12
Trouble Shooting...................................................13
Specifications.........................................................15
Replacement Parts List .......................................16
Logs installation instruction.................................20
WARNING: If the information in this
manual is not followed exactly, a f ire or
ex pl osi o n m a y r esul t causing property
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen)f r o m
i n w h i c h i t i s installed. Provisions for ad-
equate combustion and ventilation air must b e
p r o vi d e d .
R e f e r
and Ventilation section on page 4 of this manual.
World-Marketing of American,Inc.
P.O.Box 192,Rt.22 West
MillCreek,PA 17060
KOZY-WORLD PHONE NUMBER:(814)643-1775
http://www.worldmkting.com
t h e
r o o m
t o A i r
F o r Combustion
R
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l Do not touch any electrical switch; do not
use any phone in your building.
l
Immediately
neighbor's phone. Follow the gas supplier's
instructions.
l
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qu alif ied installer, service ag ency, or th e g as
supplier.
WARN ING: Im prop er
alteration, service or maintenance can cause injury or
property damage. Refer to this manual for correct in-
stallation and operational procedures. For assistance
or additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one(1)
ounce (30ml) of water for every 1,000 BTU's(.3KW's) of
gas input per hour. Refer to page 3.
Consumer: Please retain these instructions for
future use.
Installer: Please leave these instructions with the
consumer.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
1
V E N T - F R E E G A S
FIREPLACE SYSTEM
call
your gas supplier from a
installatio n, adj ustmen t,
KW-BL035-03T-0606

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GFNC2829 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kozy-World GFNC2829

  • Page 1: Table Of Contents

    Consumer: Please retain these instructions for future use. Installer: Please leave these instructions with the consumer. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. World-Marketing of American,Inc. P.O.Box 192,Rt.22 West MillCreek,PA 17060 KOZY-WORLD PHONE NUMBER:(814)643-1775 http://www.worldmkting.com KW-BL035-03T-0606...
  • Page 2: Safety Information Warnings

    WARNING gas cock must be a “T” handle within burner box or on adjacent Models GFNC2829 is equipped for type. The State of Massachusetts walls or furniture. natural gas. Field conversion is not requires that a flexible appliance 11 .
  • Page 3: Safety Information

    SAFETY INFORMATION 18. To prevent performance problems, National Fire Protection Continued do not use propane/LP fuel tank of Association, lnc. less than 100 lbs. capacity. Batterymarch Park 12. Do not run heater: Quincy. MA 02269 9. Keep all air openings in front and Where flammable liquids or This heater is designed for vent-free vapors are used or stored.
  • Page 4: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Confined and Unconfined Space Unusually Tight Construction WARNING: This heater shall not be installed in a confined space or The National Fuel Gas Code, ANS The air that leaks around doors and unusually tight construction unless Z223.1 defines a confined space as a windows may provide enough fresh provisions are provided for adequate...
  • Page 5 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 30,000 Btu/Hr Gas furnace Btu/Hr Vent-free heater 26,000 Btu/Hr Vented gas heater Btu/Hr Total 56,000 Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr...
  • Page 6: Installation

    NOTICE: This heater is in- INSTALLATION tended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central Front View heating system, system's circulating blower while using heater.
  • Page 7: Connecting To Gas Supply

    INSTALLATION Continued IMPORTANT: Install equipment shutoff valve in an accessible location. The The installer must supply an external CONNECTING TO GAS equipment shutoff valve is for turning regulator. The external regulator will SUPPLY on or shutting off the gas to the reduce incoming gas pressure.
  • Page 8: Checking Gas Connections

    INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas piping CAUTION: Make sure external WARNING: Never use an and connections for leaks after regulator has been installed between open flame to check for a leak. installing or servicing. Correct all gas supply and heater.
  • Page 9 Installing Blower Accessory Phillips head screwdriver (See Pic- ACCESSORY 20-6028 jects in blower wheel. ture 5). Tools required: Phillips screwdriver 13. Do not let the wires touch the reflec- Attach the two brackets to blower tor of the firebox. NOTICE: Shut off gas heater dur- housing using four white screws 14.
  • Page 10 Installing Blower Accessory Blower Accessory Model 20-6028 Picture 6 - Attaching Bracket To Blower Picture 7 - Routing Power Cord Picture 8 - Mouting Blower...
  • Page 11: Installing Logs

    INSTALLATION Continued INSTALLING LOGS WHAT TO DO IF YOU SMELL GAS WARNING: Failure to position Do not try to light any appliance. the parts in accordance with these Figure 11 -Control Knob and Do not touch any electrical switch; do diagrams may result in property Ignitor Button Location not use any phone in your building.
  • Page 12 INSTALLATION Continued CLEANING AND MAINTENANCE INSPECTING BURNERS C h e c k p i l o t f l a m e p a t t e r n a n d WARNING: Turn off heater and burner flame patterns often. let cool before cleaning.
  • Page 13: Troubleshooting

    CLEANING AND MAINTENANCE Continued Clean th e pilot assemb ly also. A y e l l o w t i p o n t h e p i l o t f l a m e MAIN BURNER CABINET indicates dust and dirt in the pilot Periodically inspect all burner flame Air Passageways assembly.
  • Page 14 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. Control knob not fully pressed in. ODS/pilot lights but flame goes out 1. Press in control knob fully. 2. Control knob not pressed in long when control knob is released. 2. After ODS/pilot lights, keep enough.
  • Page 15 TROUBLESHOOTING Continued REMEDY POSSIBLE CAUSE OBSERVED PROBLEM 1. Ventilate room. Stop using odor caus- Heater produces unwanted odors 1. Heater is burning vapors from paint, ing products while heater is running hair spray, glues, etc. (See IMPOR- TANT statement at beginning of 2.
  • Page 16: Specifications

    . Type of gas used (propane/LP or Purchase date Warranty card Usually, will ask you to return the defective part to the factory. SPECIFICATIONS GFPC2830 GFNC2829 Btu(Variable) Gas Type LP Gas Natural Gas Ignition Piezo Piezo Manifold Pressure 8"W.C. 3"W.C.
  • Page 17 ILLUSTRATED PARTS BREAKDOWN GFNC2829 GFPC2830 12-A 12-B 12-C 12-D 12-E...
  • Page 18 PARTS LIST This list contains replaceable parts used in your heater. When ordering GFNC2829 parts, follow the instructions listed under Replacement Parts on page 15 GFPC2830 of this manual. PART NO. DESCRIPTION ND1703X400X4 ODS 3010 (NG) ND1808X400X4 ODS 3010 (LP)
  • Page 19 ILLUSTRATED PARTS BREAKDOWN GFNC2829 GFPC2830...
  • Page 20 PARTS LIST This list contains replaceable parts used in your heater. When ordering GFNC2829 parts, follow the instructions listed under Replacement Parts on page 16 GFPC2830 of this manual. PART NO. DESCRIPTION UB28-01 Mantel BL012-01B Upper Trim BL013-01B Side Trim...
  • Page 21: Logs Installation Instruction

    LOGS INSTALLATION INSTRUCTIONS GFNC2829 GFPC2830 FIG(2) STEP 1: Install log 1 onto the two slots FIG(1) in left bracket as shown. FIG(4) FIG(3) STEP 2: Install log 2 onto the two slots STEP 3: Install log 3 onto the two slots in right bracket as shown.