Kozy-World FMK2501 Owner's Operation And Installation Manual

Compact vent-free fireplace system

Advertisement

Kozy-World
OWNER ' S OPERATION AND INSTALLATION MANUAL
FMK2501
FMK2503
FMK2502
FMK2504
Safety Information Warnings......................................2
Product Identification...................................................3
Air for Combustion and Ventilation...........................4
Installation.....................................................................6
Operating heater.........................................................10
Trouble Shooting.........................................................11
Specifications..............................................................13
Replacement Parts.....................................................14
Illustrated Parts Breakdown......................................15
Parts List.......................................................................16
Illustrated Parts Breakdown......................................17
Parts List.......................................................................18
Unpacking And Installing the Heater........................21
Installing Blower Accessory.......................................23
World marketing of American, Inc.
P. O. Box 192, Rt.. 22 West
Mill Creek, PA 17060
KOZY WORLD PHONE NUMBER :(814)643-1775
http://www.worldmkting.com
SAVE THIS MANUAL FOR FUTURE REFERENCE
R
WARNING: If the information in
this manual is not followed exactly,
a
f i r e
causing property damage, personal
injury, or loss of life.
WARNING: This is an unvented
gas-fired heater. It uses air (oxygen)
f r o m
t h e
installed. Provisions for adequate
combustion and ventilation air must
b e
p r o v i d e d .
Combustion and Ventilation section
on page 4 of this manual.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l
Do
not
any phone in your building.
l
I m m e d i a t e l y
neighbor's
phone.
instructions.
l
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency, or gas supplier.
WARNING: Improper
a l t e r a t i o n ,
can cause injury or property damage. Refer to this
m a n u a l
f o r
operational procedures. For assistance or addi-
t i o n a l
i n f o r m a t i o n
installer, service agency or gas supplier.
This appliance may be installed in an aftermarket*,
p e r m a n e n t l y
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas
i n d i c a t e d
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
COMPACT VENT-FREE
FIREPLACE SYSTEM
o r
e x p l o s i o n
m a y
r o o m
i n
w h i c h
R e f e r
t o
touch
any
electrical
switch; do not use
c a l l
y o u r g a s s u p p l i e r f r o m a
Follow
the
gas
installation, adjustment,
s e r v i c e
o r
m a i n t e n a n c e
c o r r e c t
i n s t a l l a t i o n
c o n s u l t
l o c a t e d ,
m a n u f a c t u r e d
o n
t h e
r a t i n g
r e s u l t
i t
i s
A i r
F o r
supplier's
a n d
a
q u a l i f i e d
p l a t e . T h i s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMK2501 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kozy-World FMK2501

  • Page 1: Table Of Contents

    WARNING: This is an unvented FMK2501 gas-fired heater. It uses air (oxygen) FMK2503 f r o m t h e r o o m w h i c h installed.
  • Page 2: Safety Information Warnings

    SAFETY INFORMATION WARNINGS 5. Do not use this heater as a I M P O R T A N T: R e a d t h i s WARNING: Do not use acces- wood-burning heater. Use only owner’s manual carefully and sories not approved for use with the logs provided with the heater.
  • Page 4: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Unusually Tight Construction Confined and Unconfined Space WARNING: This heater shall The air that leaks around doors not be installed in a confined space The National Fuel Gas Code, ANS and windows may provide enough or unusually tight construction Z223.1 defines a confined space as fresh air for combustion and...
  • Page 12 TROUBLE SHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame goes out 1. Control knob not fully pressed in. Press in control knob all the way. when control knob is released. 2. Control knob not pressed in long After ODS/pilot lights,...
  • Page 13: Specifications

    SPECIFICATIONS FMK2501 FMK2503 FMK2502 FMK2503 25000 25000 LP Gas Natural Gas Type Ignition Piezo Piezo Manifold Pressure 8"W.C. 3"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H × W × D) Stove 38 3/8” × 26 3/8” × 14 1/8”...
  • Page 14: Replacement Parts

    C o n t a c t a u t h o r i z e d d e a l e r s o f t h i s product. If they can't supply original replacement part(s) call KOZY-WORLD’s Technical Service Department at (814)643- 1775 for referral information. When calling KOZY-WORLD or your dealer,have ready: Your name Your address Model...
  • Page 16: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 14 of this manual. FMK2501 FMK2502 FMK2503 FMK2504 " 3 " 8...
  • Page 17: Illustrated Parts Breakdown

    ILLUSTRATED PARTS BREAKDOWN FMK2501 FMK2502 FMK2503 FMK2504...
  • Page 18: Parts List

    PARTS LIST FMK2501 FMK2502 FMK2503 FMK2504...

Table of Contents