Kozy-World FMK2501 Owner's Operation And Installation Manual

Advertisement

Kozy-World
OWNER ' S OPERATION AND INSTALLATION MANUAL
FMK2501
FMK2502
FMK2503
FMK2504
GFN2505
GFP2506
Tabel of Contents
Safety Information Warnings......................................2
Air for Combustion and Ventilation............................4
Installation.......................................................................6
Operating heater............................................................9
Trouble Shooting..........................................................11
Specifications..............................................................13
Replacement Parts.....................................................14
Parts List.......................................................................16
Installing the Heater....................................................19
Installing Blower Accessory.....................................20
WARNI NG : I f the in fo rmatio n i n
this manual is not followed exactly, a
fi re o r e xp l o si o n m ay r es u l t caus-
ing property damage, personal injury,
or loss of life.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) f r o m
t h e r o o m i n w h i c h i t i s installed.
Provisions for adequate combustion and
ventilation air must b e
R e f e r
t o A i r
F o r Combustion and
Ventilation section on page 4 of this
manual.
World Marketing of America, Inc.
P. O. Box 192, Rt.. 22 West
Mill Creek, PA 17060
KOZY WORLD PHONE NUMBER :(814)643-1775
http://www.worldmkting.com
R
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance
WHAT TO DO IF YOU SMELL GAS
l
l
not use any phone in your building.
l
neighbor's phone. Follow the gas supplier's
instructions.
l
call the fire department.
Installation and service must be performed by
a qualified installer, service agency, or gas
supplier.
alteration, service or maintenance can cause injury
or property damage. Refer to this manual for correct
installation and operational procedures. For assis-
tance or additional information consult a qualified
installer, service agency or gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
Water vapor is a by-product of gas combustion.An unvented
p r o v i d e d .
room heater produces approximately one (1) ounce (30ml) of
water for every 1,000 BTU's (.3KW's) of gas input per hour.
Refer to page 3.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for future
use.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
1
COMPACT VENT-FREE
FIREPLACE SYSTEM
Do not try to light any appliance.
Do not touch any electrical switch; do
Immediately call your gas supplier from a
If
you
cannot reach your gas supplier,
WARNING: Improper
WATER VAPOR:
A BY-PRODUCT OF UNVENTED ROOM HEATERS
.
installation, adjustment,
KW-EL026-01W-0503

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMK2501 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kozy-World FMK2501

  • Page 1: Table Of Contents

    FIREPLACE SYSTEM OWNER ’ S OPERATION AND INSTALLATION MANUAL Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this FMK2501 or any other appliance WHAT TO DO IF YOU SMELL GAS FMK2502 Do not try to light any appliance.
  • Page 2: Safety Information Warnings

    It is your guide to safe 11 . T h is h ea t e r n e ed s f r es h ai r WARNING: Models FMK2501 ventilation to run properly. This and proper operation of this heater.
  • Page 3: Local Codes

    LOCAL CODES UNPACKING SAFETY INFORMATION 1. Remove top inner pack. lnstall and use heater with care. Continued 2. Tilt carton so that fireplace is upright. Fol low all local codes. In the 3. Remove protective side packaging. absence of local codes, use the 15.
  • Page 4: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Unusually Tight Construction Confined and Unconfined Space WARNING: This heater shall The air that leaks around doors not be installed in a confined space The National Fuel Gas Code, ANS and windows may provide enough or unusually tight construction Z223.1 defines a confined space as fresh air for combustion and...
  • Page 5 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 30,000 Btu/Hr Gas furnace Btu/Hr Vent-free heater 26,000 Btu/Hr Vented gas heater Btu/Hr Total 56,000 Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr...
  • Page 6: Installation

    INSTALLATION NOTICE: This heater is in- tended for use as supplemental heat. Use this heater along with your primary heating system. Do install this heater as your primary heat source. If you have a central heating system, you may run system's circulating blower while using heater.
  • Page 7 INSTALLATION Continued CONNECTING TO GAS SUPPLY The installer must supply an external IMPORTANT: Install equipment shutoff regulator. The external regulator will re- valve in an accessible location. The WARNING: A qualified service per- duce incoming gas pressure. You must equipment shutoff valve is for turning on son must connect heater to gas supply.
  • Page 8 INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Never use an open WARNING: Test all gas piping CAUTION: Make sure external flame to check for a leak. Apply a and connections for leaks after install- regulator has been installed be- mixture of liquid soap and water to ing or servicing.
  • Page 9: Installing Logs

    INSTALLATION Continued INSTALLING LOGS C. Use only your hand to push in or turn l No te : If pilot do es n ot st ay lit, the gas control knob. Never use tools. If the c o n t a c t a q u a l i f i e d s e r vi c e WARNING: Failure to position knob will not push in or turn by hand, don't p e r s o n o r g a s s u p p l i e r f o r...
  • Page 10: Cleaning&Maintenance

    OPERATING HEATER Continued THERMOSTAT CONTROL CLEANING AND MAINTENANCE INSPECTING BURNERS OPERATION C h e c k p i l o t f l a m e p a t t e r n a n d WARNING: Turn off heater and burner flame patterns often.
  • Page 11: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Continued MAIN BURNER C lean t h e p ilo t assem b ly also . A CABINET Periodically inspect all burner flame y e l l o w t i p o n t h e p i l o t f l a m e Air Passageways h oles wit h t he healer run n in g.
  • Page 12 TROUBLE SHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. Control knob not fully pressed in. ODS/pilot lights but flame goes out Press in control knob all the way. when control knob is released. 2. Control knob not pressed in long Af t er OD S /p ilo t lig h t s,...
  • Page 13: Specifications

    SPECIFICATIONS FMK2501 FMK2502 FMK2503 FMK2504 GFN2505 GFP2506 20,000/25,000 20,000/ 25,000 LP Gas Natural Gas Type Ignition Piezo Piezo Manifold Pressure 8"W.C. 3"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H × W × D) Stove 38 3/8”...
  • Page 14: Replacement Parts

    Flexible gas hose is used for connecting Technical Service Department at (814)643- the heater to gas suppy.The flexible gas 1775 for referral information. hose must be CSA approved. When calling KOZY-WORLD or your dealer,have ready: Your name Your address Model...
  • Page 15 ILLUSTRATED PARTS BREAKDOWN FMK2501 FMK2502 FMK2503 FMK2504 GFN2505 GFP2506...
  • Page 16: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 14 of this manual. FMK2501 FMK2502 FMK2503 FMK2504 GFN2505 GFP2506 PART GFN2505 250TYLA 250TYLB FMK2501~2504 DESCRIPTION GFP2506...
  • Page 17 ILLUSTRATED PARTS BREAKDOWN FMK2501 FMK2502 FMK2503 FMK2504...
  • Page 18 PARTS LIST FMK2501 FMK2502 FMK2503 FMK2504 PART DESCRIPTION NUMBER EB33000 Decorating Logs Assembly EL040-01A Top Panel EL016-01 Middle Decorating Panel EL015-01 Side Panel EL019-01 Back Panel EL004-01 Regulator Bracket EL010-01C Upper Decorating Frame EL011-01 Upper Decorating Wire EL002(03)-01 Upper (Mid) Louver...
  • Page 19: Installing The Heater

    ILLUSTRATED PARTS BREAKDOWN GFN2505 GFP2506...
  • Page 20 PARTS LIST GFN2505 GFP2506 PART NUMBER DESCRIPTION EL(N)250- EL(N)250- EL(N)250- GFN2505 TYLB-O TYLB-C TYLB-DO GFP2506 Decorating Logs EB33000 Assembly EL040-01B-O Top Panel (B) EL040-01B-C Top Panel (B) EL040-01B-DO Top Panel (B) EL016-06-O Middle Decorating Panel EL016-06-C Middle Decorating Panel EL016-06-DO Middle Decorating Panel EL015-06-O Left (Right) Side Panel...
  • Page 21 1. Install legs and pedestal decorating trim. Except model GFN2505 GFP2506 Lay the heater down on its back and install the legs with care on the bottom panel (as shown in Figure 1). Make sure the vein side is forwards. Figure 1 l Install the pedestal decorating trim (front and side) under the pedestal with screws.
  • Page 22: Installing Blower Accessory

    INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL 20-6029 ACCESSORY 20-6029 to rear panel. Draw the four strand cable in blower wheel. backward so as to expose the three Tools required: Philips screwdriver Use screws provided in blower kit to black, green, white lines on the four assemble the plate which assembled strand cable at the back of rear panel.
  • Page 23 INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL NFHTX186 Figure 3-A Routing Power Cord Wiring Diagram Decal Figure 3-B Routing Power Cord MODEL GFN2505 GFP2506 Figure 5 Mounting Control Housing Figure 4 Mounting Control hosing...

This manual is also suitable for:

Fmk2502Fmk2503Fmk2504Gfn2505Gfp2506

Table of Contents