On-Screen Frequency Change Options
When Avoidance mode is set to Prompt, the following on-screen options are available when interference is detected:
•
Switch: Deploys a clear backup frequency from the Spectrum Manager when selected
•
Manual: Accesses the frequency menu to make a frequency change using the control wheel
•
Ignore: Suppresses the interference warning message
Detection Sensitivity
The sensitivity setting allow you to vary the timing of warning messages to match the RF conditions and the need to avoid in
terference.
Normal
•
Generates a message in response to low levels of interference well below the audibility threshold
•
Provides more time to react to messages
•
Interference Detection is suppressed when received signal strength is below the Exclusion threshold
More Sensitive
•
Generates a message in response to moderate levels of interference below the audibility threshold
•
Provides more time to react to messages
•
Interference Detection can trigger at low received signal levels, regardless of the Exclusion threshold setting
Less Sensitive
•
Detects interference at a level just below the audibility threshold
•
Fewer detection messages
•
Less time to react to messages
•
Interference Detection is suppressed when received signal strength is below the Exclusion threshold
Setting up an Audio Channel
Setting the Frequency Band
Set to the Receiver to the same frequency band as the transmitter.