DANGER
Electric shock
Death or serious personal injury
- Route the power cable in a way
that supports it and protects it from
being cut, pinched or damaged.
- If the power cable is cut, pinched,
or damaged, replace it before
using the product.
DANGER
Electric shock
Death or serious personal injury
- Do not remove the power cable
and strain relief.
- Do not connect electrical conduit to
the pump.
Use an approved level controller with
a current rating that matches the
service factor marked on the
product's nameplate.

4.1 Pipe connection

Threaded steel or rigid plastic pipes can be screwed
directly into the 1.5" NPT outlet port. For permanent
installation, we recommend that you fit a union, a
non-return valve and an isolating valve in the outlet
pipe.
Other recommendations:
For portable or temporary installations, a plastic
outlet pipe can be used in conjunction with a
suitable, screwed connection or a hose coupling.
Threads must be sealed using Teflon
Do not install the pump hanging from
the outlet pipe or hose.
Do not lift the pump by its power
cable. Lower and lift it by means of a
wire or chain fastened to the pump
handle.

4.2 Minimum space

When the pump is installed in a permanent
installation with a float switch, and the cable length is
set to the minimum length of at least 4 in. (100 mm),
the minimum dimensions of the sump pit, basin or
tank must be as shown in fig. 2.
In addition, the sump pit, basin or tank must be sized
according to the relation between the water flow to
the sump pit, basin or tank and the pump
performance.
Fig. 2

4.3 Location

The pump can be used in vertical as well as
horizontal position with the outlet port as the highest
point of the pump. See fig. 3.
During operation, the inlet strainer must always be
completely covered by the pumped liquid.
Fig. 3
®
tape.
When the pipe or hose has been connected, place
the pump in its operating position.
Position the pump so that the inlet strainer will not be
blocked by sludge, mud or similar materials.
In a permanent installation, the installation site must
be cleared of sludge, pebbles, etc. before the pump
is installed.
We recommend that you place the pump on a solid
base. See fig. 4.
Fig. 4
21.5 in. (550 mm)
550 mm
Minimum installation dimensions
Pump positions
Pump placed on a plate
5